— 49 —
SPECIFICATIONS
MEASUREMENT CONDITIONS
1. Standard voltage:
Handset:
DC 3.6 V ±0.025 V
Base:
AC 120 V
±
3 V 60 Hz
2. Temperature:
25°C
±
5 °C
3. Channel:
CH
Handset (TX Frequency)
Base (TX Frequency)
1
48.760 MHz
43.720 MHz
2
48.840 MHz
43.740 MHz
3
48.860 MHz
43.820 MHz
4
48.920 MHz
43.840 MHz
5
49.020 MHz
43.920 MHz
6
49.080 MHZ
43.960 MHz
7
49.100 MHz
44.120 MHz
8
49.160 MHz
44.160 MHz
9
49.200 MHz
44.180 MHz
10
49.240 MHz
44.200 MHz
11
49.280 MHz
44.320 MHz
12
49.360 MHz
44.360 MHz
13
49.400 MHz
44.400 MHz
14
49.460 MHz
44.460 MHz
15
49.500 MHz
44.480 MHz
16
49.670 MHz
46.610 MHz
17
49.845 MHz
46.630 MHz
18
49.860 MHz
46.670 MHz
19
49.770 MHz
46.710 MHz
20
49.875 MHz
46.730 MHz
21
49.830 MHz
46.770 MHz
22
49.890 MHz
46.830 MHz
23
49.930 MHz
46.870 MHz
24
49.990 MHz
46.930 MHz
25
49.970 MHz
46.970 MHz
4. Telephone Line Voltage/Load:
DC 48 V
±
2 V/600 ohm
5. Ring Frequency:
20 Hz
6. Ring Duration:
2 sec ON, 4 sec OFF
7. Standard Modulation:
1 kHz
±
3 kHz Dev.
8. Secure Code:
65536 Combination
9. Method of Measurement:
According to EIA Standard, RS-316A
10. Portable RX Load:
150 ohm
Summary of Contents for FT-7807R
Page 1: ...CORDLESS TELEPHONE SERVICE MANUAL PUBLISHED IN JAPAN Jun 1998 FT 7807R FILE NO 2B0 9803 ...
Page 8: ... 7 ...
Page 9: ... 8 ...
Page 11: ... 11 12 TEST POINT RF TEST POINT RX VCO TEST POINT Discriminator TEST POINT TX VCO ...
Page 26: ... 27 ...
Page 27: ... 28 ...
Page 28: ... 29 ...
Page 29: ... 30 EXPLODED VIEW AND MECHANICAL PARTS LIST Base Unit ...
Page 31: ... 32 Handset ...
Page 52: ...MECHANICAL PARTS LIST ...