45
SPECIFICATIONS
MEASUREMENT CONDITIONS
1. Standard Voltage
:Portable Unit
.... DC 3.8V ± 0.025V
:Base Unit
.... AC 120V ± 3V 60Hz
2. Temperature
:25
℃
± 5
℃
3. Channel
CH
Portable(TX Frequency)
Base(TX Frequency)
1
902.119024MHz
924.996683MHz
2
902.218927MHz
925.096585MHz
3
902.318829MHz
925.196488MHz
4
902.418732MHz
925.296390MHz
5
902.518634MHz
925.396293MHz
6
902.618537MHz
925.496195MHz
7
902.718439MHz
925.596098MHz
8
902.818341MHz
925.696000MHz
9
902.918244MHz
925.795902MHz
10
903.018146MHz
925.895805MHz
11
903.118049MHz
925.995707MHz
12
903.217951MHz
926.095610MHz
13
903.317854MHz
926.195512MHz
14
903.417756MHz
926.295415MHz
15
903.517659MHz
926.395317MHz
16
903.617561MHz
926.495220MHz
17
903.717463MHz
926.595122MHz
18
903.817366MHz
926.695024MHz
19
903.917268MHz
926.794927MHz
20
904.017171MHz
926.894829MHz
21
904.117073MHz
926.994732MHz
22
904.216976MHz
927.094634MHz
23
904.316878MHz
927.194537MHz
24
904.416780MHz
927.294439MHz
25
904.516683MHz
927.394341MHz
26
904.616585MHz
927.494244MHz
27
904.716488MHz
927.594146MHz
28
904.816390MHz
927.694049MHz
29
904.916293MHz
927.793951MHz
30
905.016195MHz
927.893854MHz
4. Tel. Line Voltage/Load
: DC 48V ± 2V / 600 OHMS
5. Ring Frequency
: 20 Hz
6. Ring Duration
: 2 Sec ON, 4 Sec OFF
7. Standard Deviation
: ± 30KHz Dev.
8. Secure Code
: 65536 Combinatin
9. Method of Measurement
: According to EIA Standard RS-316A
10. Portable RX AF Load
: 150 OHMS
Summary of Contents for FD-4809
Page 1: ...CORDLESS TELEPHONE PUBLISHED IN JAPAN Nov 1999 SERVICE MANUAL FILE NO 2B0 9909 FD 4809 ...
Page 8: ...7 BLOCK DIAGRAMS Base Unit ...
Page 9: ...8 Handset ...
Page 10: ...9 10 SCHEMATIC DIAGRAMS Base Unit ...
Page 11: ...11 12 Handset ...
Page 25: ...26 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 26: ...27 Handset Main PCB ...
Page 27: ...28 WIRING DIAGRAMS Base Unit ...
Page 28: ...29 Handset ...
Page 47: ......