Setting Mode (08) Codes
05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Fuser
2002
-
Fuser unit error status
counter
0
0-62
M
0: No error 1: C411 error 2: C412 error 3: C413 error 4:
C414 error 5: C415 error 7: C447 error 9: C449 error 19:
C449 error 21: C449 error 22: C449 error 23: C449 error
24: C447 error 25: C449 error 27: C449 error 45: C449
error 62: C452 error
Than the above: C4B0
1
Y
Y
08
Setting
mode
Process
Fuser
2009
-
Fuser roller
temperature on
standby (Center
thermistor)
8
0-12
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6: 170
degrees C 7: 175 degrees C 8: 180 degrees C 9: 185
degrees C 10: 190 degrees C 11: 195 degrees C 12: 200
degrees C
1
Y
Y
08
Setting
mode
Process
Fuser
2010
-
Fuser roller
temperature during
printing (Center
thermistor/Plain paper)
8
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6: 170
degrees C 7: 175 degrees C 8: 180 degrees C 9: 185
degrees C 10: 190 degrees C 11: 195 degrees C 12: 200
degrees C 13: 205 degrees C 14: 210 degrees C
1
Y
Y
08
Setting
mode
Process
Fuser
2040
-
Drop control when
ready
1
0-2
M
0: Invalid, 1: Valid, 2: Invalid in low temperature
1
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Center
thermistor)
2041
0
The first drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Center
thermistor)
2041
1
The second drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Center
thermistor)
2041
2
The third drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting in ready
status (Center
thermistor)
2041
3
The fourth drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Fuser roller
temperature
Energy
Saving
Mode
2042
-
Center thermistor
0
0-13
M
0: OFF 1: 40 degrees C 2: 50 degrees C 3: 60 degrees C
4: 70 degrees C 5: 80 degrees C 6: 90 degrees C 7: 100
degrees C 8: 110 degrees C 9: 120 degrees C 10: 130
degrees C 11: 140 degrees C 12: 150 degrees C 13: 160
degrees C
1
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-29
e-STUDIO2006/2306/2506/2007/2307/2507