– 9 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
REPLACEMENT OF THE CRT
Service parts are provided for each R, G and B.
The contents of the parts are as follows.
R
G
B
40"
23003518
23003519
23003520
56"
23003817
23003781
23003818
65"
23003780
23003781
23003782
REPLACEMENT OF HIGH VOLTAGE CABLE
ANODE LEAD
RUBBER BOOT
LEAD HOLDER
Z450 TPA5007
Fig. a
1. When replacing Anode Lead or Anode Cap with new
one, remove Lead Holder from old lead as shown in
figure below, and put it on new lead. Do not throw away
Lead Holder.
NOTE : THE LEAD HOLDER IS ATTACHED TO
TPA5007 (Z450), BUT IS NOT ATTACHED TO
ANODE LEAD AND ANODE CAP. RUBBER
BOOT IS ATTACHED TO ANODE LEAD AND
ANODE CAP.
2. Detaching Lead Holder
RUBBER BOOT
OLD
ANODE LEAD
or
ANODE CAP
LOCK
LEAD HOLDER
Cut here rubber boot
and lead together to
detach Lead Holder.
Fig. b