6.1 RAS
Unified Controller nv Series DeviceNet Module DN611B Instruction Manual
115
■Execution node information
When request information type 3 is set for RAS information read request, slave device execution information
(module status and node status) can be read into the acknowledgement area.
Acknowledgement Area
F
8 7
0
02D0H Request code (0015H)
02D1H Completion status
02D2H Number of RAS information
words
64 words
02D3H Execution node information
:
0312H
1) Module Status (02D3H to 02F2H: 32 words)
The 02D3H to 02F2H in the acknowledgement area represent module status. Module status indicates in
code the operations of the DN611B for the slave devices and the network. "NA = [ ]" in Table 6-20 shows a
node address.
Table 6-20 Module Status
F
8 7
0
F
8 7
0
02D3H
NA=1
NA=0
02E3H
NA=33
NA=32
02D4H
NA=3
NA=2
02E4H
NA=35
NA=34
02D5H
NA=5
NA=4
02E5H
NA=37
NA=36
02D6H
NA=7
NA=6
02E6H
NA=39
NA=38
02D7H
NA=9
NA=8
02E7H
NA=41
NA=40
02D8H
NA=11
NA=10
02E8H
NA=43
NA=42
02D9H
NA=13
NA=12
02E9H
NA=45
NA=44
02DAH
NA=15
NA=14
02EAH
NA=47
NA=46
02DBH
NA=17
NA=16
02EBH
NA=49
NA=48
02DCH
NA=19
NA=18
02ECH
NA=51
NA=50
02DDH
NA=21
NA=20
02EDH
NA=53
NA=52
02DEH
NA=23
NA=22
02EEH
NA=55
NA=54
02DFH
NA=25
NA=24
02EFH
NA=57
NA=56
02E0H
NA=27
NA=26
02F0H
NA=59
NA=58
02E1H
NA=29
NA=28
02F1H
NA=61
NA=60
02E2H
NA=31
NA=30
02F2H
NA=63
NA=62
Summary of Contents for DeviceNet nv Series