Toshiba BMS-IWF0320E Installation Manual Download Page 3

Smart device control interface

Installation Manual

3-

EN

Precautions for safety

• Carefully read these "Precautions for Safety" before installation, and perform installation work safely.
• These precautions contain important information regarding safety.
• After installation work, carry out an operation trial to confirm that there are no problems, and explain to the customer how to 

operate and maintain the system. Ask the customer to keep this Installation Manual.

Expressions

Graphic symbols

Warning

Text set off in this manner indicates that failure to adhere to the directions in the warning could result 
in serious bodily harm (*

1

) or loss of life if the product is handled improperly.

Caution

Text set off in this manner indicates that failure to adhere to the directions in the caution could result 
in serious bodily injury (*

2

) or damage (*

3

) to property if the product is handled improperly.

*1: Serious bodily harm indicates loss of eyesight, injury, burns, electric shock, bone fracture, poisoning, and other injuries which 

leave aftereffect and require hospitalization or long-term treatment as an outpatient.

*2: Bodily injury indicates injury, burns, electric shock, and other injuries which do not require hospitalization or long-term treatment 

as an outpatient.

*3: Damage to property indicates damage extending to buildings, household effects, domestic livestock, and pets.

" " indicates prohibited items.
The actual contents of the prohibition are indicated by a picture or text placed inside or next to the 
graphic symbol.

" " indicates compulsory (mandatory) items.
The actual contents of the obligation are indicated by a picture or text placed inside or next to the 
graphic symbol.

 Warning

• Installation and reinstallation should be performed by your dealer or a qualified 

electrician

Attempting to carry out installation work on your own, and doing so incorrectly, may result in 
electric shock or fire.

• Electrical work must be performed by a qualified electrician in accordance with 

this Installation Manual. The work must satisfy all local, national and international 
regulations

Inappropriate work may result in electric shock or fire.

• Be sure to turn off the power before starting work

Failure to do so may result in electric shock.

• Use only the power adapter supplied with this unit

A power adapter other than that supplied with this unit may provide a different voltage and have 
different polarity (+) (

), which could lead to fire, explosion or generation of heat.

• Do not modify the unit

Doing so may result in excessive heat or fire.

The following instructions 
must be observed.

Prohibited

Compulsory

Warning

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may 
be required to take adequate measures.

Summary of Contents for BMS-IWF0320E

Page 1: ...English Smart device control interface Model name BMS IWF0320E BMS IWF0320IN for India only Installation Manual ...

Page 2: ...utions for safety 3 Introduction 4 1 Installation 7 2 Power and signal line connections 9 3 Settings 11 3 1 Switch setting 11 3 2 LED 12 3 3 Wireless router setting 12 3 4 Application setting 12 3 5 Smartphone Tablet setting 12 3 6 Factory default setting 13 4 Test run 13 ...

Page 3: ...y indicates damage extending to buildings household effects domestic livestock and pets indicates prohibited items The actual contents of the prohibition are indicated by a picture or text placed inside or next to the graphic symbol indicates compulsory mandatory items The actual contents of the obligation are indicated by a picture or text placed inside or next to the graphic symbol Warning Insta...

Page 4: ... Use screws to secure the unit in locations without DIN rails walls etc Screws M4 x 12 2 For securing the DIN rails Rubber feet 4 For levelling the unit Screws M3 x 8 4 For securing the rubber feet to the unit DVD R 1 Manual Installation Manual 1 This manual Owner s Manual 1 Tie wrap 1 Model name BMS IWF0320E BMS IWF0320IN Power supply Rated voltage 220 240 VAC 50 60 Hz 5 VDC Power consumption 3 W...

Page 5: ... confirms to specification of BMS IWF0320IN Specifications Output DC 5 V 5 Current 2 A to 3 A DC Plug Use a power adapter that complies with BIS standards We also recommend that the power adapter complies with safety designs EN60950 EMI standards EN550022 and EN61000 3 and EMS standards including EN550024 and EN61000 4 Supplying power other than 5 V may cause malfunctions 2 1 mm Ø inner diameter 5...

Page 6: ...mes Name Function 5V DCIN Connect the power adapter USB For service Ethernet LAN Connect to the Building Management System Shutdown button Shutdown L1 Power indicator L2 Boot status indicator 140 90 POWER TCC LINK CPU ERROR USB L2 L1 5V DCIN Ethernet LAN Shutdown button ...

Page 7: ...sing the DIN rail to mount the unit or wall mount or surface mount it as shown below Use the supplied mounting bracket to wall mount or surface mount the interface 3 Surface mount Use screws to secure the supplied rubber legs to the interface before surface mounting it 1 DIN rail mount Install the interface on DIN rails mounted on a switchboard or elsewhere Front view Back view 2 Wall mount Use sc...

Page 8: ...n Manual 8 EN Installation Space and Maintenance Space A side space for connecting through cable inlets and an upper space for maintenance must be reserved before installation The other sides can be adjacent to surrounding objects 100 mm 100 mm ...

Page 9: ...nd TCC LINK communication cable connection No Line Description 1 For TCC LINK Type 2 core shielded wires Wire size 1 25 mm2 1000 m max total length including air conditioner wiring length Length 2 00 mm2 2000 m max 2 For Ethernet Type LAN cable higher than Category 5 UTP The appropriate use of straight cable cross cable should be done depending on your system used Length 100 m max 50 10 Connect th...

Page 10: ...PU ERROR HUB U2 U1 U3 U4 U3 U4 U2 U1 U2 U1 U2 U1 w w Smart device control interface wireless router Power adapter Power Supply TCC LINK main bus Outdoor unit Outdoor unit Indoor unit Indoor unit Remote controller Remote controller modem Smartphone Tablet You do not need to connect to a modem if you are not doing operations over the internet ...

Page 11: ...ts to OFF SW302 Test button Not used during normal operation SW100 TCC LINK terminator resistor setting switch Set the TCC LINK terminator resistor on the air conditioner side Set SW100 to OFF SW700 Shutdown function button Use this button to stop network process of the Smart device control interface SW100 SW300 SW302 SW301 SW700 ...

Page 12: ...or tablet to confirm the connections to the wireless router If you are using the product over the internet you need to connect the Smart device control interface that is connected to the wireless router to the internet Confirm that your smartphone or tablet which is connected to the wireless router can connect to the internet LED LED color Use POWER Red Power indicator TCC LINK Orange TCC LINK com...

Page 13: ...ol interface After turning on the power confirm that the power LED lights Five minutes after turning on the power confirm that the TCC LINK LED and the CPU LED are flashing Check the following items because they may cause these LEDs to not flash Confirm communication with the Smart device control interface You need to log in to operate the air conditioner from the controller Refer to the Owner s M...

Page 14: ...er the following items are the cause that you cannot log in Cause Action The wireless router cannot connect to the internet Refer to the manual for the wireless router to do the settings again If an internet service provider permanently registered the user s PC or MAC address Identification number of the modem the Smart device control interface may not be connected to the internet Contact the inte...

Page 15: ...DEA6729101 ...