● Register
IIDC2 address
Register
address
Read
Write
Memory
save
Default
Register name
Description
0x0021 F31C
R/W
✓
0x0
SequentialShutter
Enable
Sets the activation of Sequential Shutter (SS) function.
0x0:OFF,0x1:ON
0x0021 F33C
R/W
✓
0x1
SequentialShutter
TerminateAt
Sets the number of Tables to repeat the sequence.
Min:0x1(1),Max:0x10(16)
0x0050 0040
R/W
✓
0x1
SequentialShutter
Entry1
Sets the UserSet number [1] to register to the first sequence.
Min:0x1(1),Max:0xF(15)
0x0050 0044
R/W
✓
0x1
SequentialShutter
Entry 2
Sets the UserSet number [2] to register to the first sequence.
Min:0x1(1),Max:0xF(15)
↓
↓
↓
0x0050 0074
R/W
✓
0x1
SequentialShutter
Entry 15
Sets the UserSet number [15] to register to the first sequence.
Min:0x1(1),Max:0xF(15)
0x0050 0078
R/W
✓
0x1
SequentialShutter
Entry 16
Sets the UserSet number [16] to register to the first sequence.
Min:0x1(1),Max:0xF(15)
Legacy address
Register
address
Read
Write
Memory
save
Default
Register name
Description
0xF0
R/W
✓
0x0
SequentialShutter
Enable
0x0:OFF
、
0x1:ON
0xF1
R/W
✓
0x1
SequentialShutter
TerminateAt
Sets the number of Tables to repeat the sequence.
0x1
~
0x4
0xF3
R/W
✓
0x1
SequentialShutter
Entry 1
Sets the UserSet number to register to the first sequence.
0x1
~
0x4
0xF4
R/W
✓
0x1
SequentialShutter
Entry 2
Sets the UserSet number to register to the 2nd sequence.
0x1
~
0x4
0xF5
R/W
✓
0x1
SequentialShutter
Entry 3
Sets the UserSet number to register to the 3rd sequence.
0x1
~
0x4
0xF6
R/W
✓
0x1
SequentialShutter
Entry 4
Sets the UserSet number to register to the 4th sequence.
0x1
~
0x4
0xF7
W.O.
-
-
SequenceMemory
Load
0x1: Load the parameters from the memory specified [Memory bank] register.
0xF8
W.O.
-
-
SequenceMemory
Save
0x1: Save the parameters from the memory specified [Memory bank] register.
If camera teruned off, the data in memory for SS is erased.
●
Control procedure
- Set the camera parameters and save them to UserSet. Repeat this as you required.
Please refer to the section of ‘UserSetControl’ for how to operate UserSet.
- Sets the UserSet number to register to the sequence to ‘SequentialShutterEntry’. Repeat this as you
required.
- Set the number of Index to repeat the sequence to ’SequentialShutterTerminateAt’.
- Set the activation of SequentialShutter function by ‘SequentialShutterEnable’.
● Note
Contents saved using ‘SequenceMemorySave’ of Legacy address control are saved in volatile memory.
Therefore, the contents saved using ‘SequenceMemorySave’ will disappear when the power is turned off.