72
−
FILE NO. SVM-04007
10-4. Outdoor Unit (RAS-18UA-ES3, RAS-18UA-AS3)
1)
Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2)
Remove the electrical parts cover.
(2 screws
∅
4 x 10L)
3)
Remove 2 cord clamps (4 screws
∅
4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screws on the terminal block
and 1 ground screw on the electrical parts base.
4)
Remove the front cabinet. (8 scerws
∅
4 x 10L)
(Pull the front lower portion toward you, and pull out
it upward to remove it.)
5)
Remove the back cabinet. (4 screws
∅
4 x 10L)
1)
Perform the common procedure
1
2)
Remove the capacitor band. (1 screw
∅
4 x 10L)
3)
Disconnect the lead wires from the capacitor
terminal.
1)
Perform the common procedur
e
1
2)
Remove the fixing screw. (1 screw
∅
4 x 10L)
3)
Disconnect the lead wires from the capacitor
terminal.
1)
Perform the common procedure
1
2)
3)
Disconnect the lead wires from the relay terminal.
1)
Perform the common procedure
1
2)
Remove the fixing screw. (1 screw
∅
4 x 10L)
3)
Disconnect the lead wires from the terminal.
1
Common
procedure
2
Running
capacitor
for compressor
3
Running
capacitor
for fan motor
4
Magnetic
5
Spark killer
No.
Part name
Procedures
Remarks
Remove
8 screws
∅
4 x 10L
4 screws
∅
4 x 22L
4 screws
∅
4 x 10L
Remove the fixing screw. (
2
screw
∅
4 x 10L)
contactor
Spark killer
Running
capacitor for
compress or
Running
capacitor for
fan motor
Magnetic
contactor