![Toshiba 36HF70 Service Manual Download Page 10](http://html.mh-extra.com/html/toshiba/36hf70/36hf70_service-manual_431085010.webp)
– 10 –
GENERAL ADJUSTMENTS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23 * * * * * *
POWER : 000
BUS LINE : OK
BUS CONT : OK
BLOCK : UV V1 V2
or QV01 QV01S
SYNC
���
���
���
���
���
���
Part number of microprocessor (QA01)
���
Operation number of protection circuit (current limiter) . . . . “000” is normal.
���
BUS line check
“OK” ................... Normal
“SCL-GND” or “NG” .......... SCL-GND short circuit
“SDA-GND” or “NG” .......... SDA-GND short circuit
“SCL-SDA” or “NG” ........... SCL-SDA short circuit
���
BUS line ACK (acknowledge) check
“OK” ..................... Normal
Display of Location Number . . . . NG
(Display example)
“QA02 NG”, “H001 NG”, “Q501 NG” etc.
Note: The indication of failure place is only one place though failure places are plural. When
repair of a failure place finishes, the next failure place is indicated. (The order of priority of
indication is left side.)
���
Sync. signal check
Green display ..... Normal
Cyan display ...... No check
Red display ........ NG
UV ........... TV mode
V1 ........... VIDEO 1 mode
V2 ........... VIDEO 2 mode
*
The items marked with
are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.
Summary of Contents for 36HF70
Page 43: ... 43 44 SIGNAL CONV BOARD PB9568 BOTTOM FOIL SIDE ...
Page 44: ... 45 46 POWER DEF BOARD PB9565 BOTTOM FOIL SIDE ...
Page 45: ... 47 48 CONTROL 1 BOARD PB9570 BOTTOM FOIL SIDE ...
Page 46: ... 49 50 CONTROL 2 BOARD PB9571 BOTTOM FOIL SIDE ...
Page 47: ... 51 52 HYPER PRO BOARD PB9584 BOTTOM FOIL SIDE CRT VM BOARD PB9569 BOTTOM FOIL SIDE ...