– 8 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23
******
POWER : 000
BUS LINE : OK
BUS CONT : OK
BLOCK : MAIN
SET ID : 03
E2P VER : 02
OPT0 : 20H OPT1 : 84H OPT2 :01H
���
���
���
���
���
���
���
���
���
Part number of microprocessor (QA01)
���
Operation number of protection circuit (current limiter) . . . . “000” is normal.
���
BUS line check
“OK” ................... Normal
“SCL-GND” or “NG” .............. SCL-GND short circuit
“SDA-GND” or “NG” ............. SDA-GND short circuit
“SCL-SDA” or “NG” .............. SCL-SDA short circuit
���
BUS line ACK (acknowledge) check
“OK” ..................... Normal
Display of Location Number . . . . NG
(Display example)
“QA02 NG”, “H001 NG”, “Q501 NG” etc.
Note: The indication of failure place is only one place though failure places are plural. When repair
of a failure place finishes, the next failure place is indicated. (The order of priority of indica-
tion is left side.)
���
SYNC signal available/not available (available: green, not available: red)
���
SET ID
���
Version of E2P
���
OPT data
*
The item marked with
are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.
Summary of Contents for 36A43
Page 24: ... 24 SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 25: ... 25 26 MAIN BOARD PD1050B BOTTOM FOIL SIDE ...
Page 28: ... 30 GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS QZ01 FILTER QG01 MTS Q830 CIRCUIT BLOCK DIAGRAM ...
Page 30: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...