MAIN BOARD EXCHANGE
When Main board is exchanged, the Application SW (Firrmware) and Model Setting need to
be updated.
Please update in the following procedures.
Updating of Software and Model Setting
1. Copy the Application SW (Firmware) file and the Model Setting file to the root of the USB
mass storage device.
Application SW:
[Example] UPDATE_50L7363C_12800_INIT_CLEAR#.enc
Model Setting File:
This Application SW is for not
only 50L7363C but also the other
models, i.e. all of L73/L63/L43
models.
This number is
an example.
This SW is encrypted for
security.
“enc” means encrypted.
Model setting files are categorized by shipout.
Each Shipout folder contains model setting files.
[Example] Model_Setting_L4333_32_A.bin
TV series
Panel size
Panel Vendor