- 9 -
8.
SELF DIAGNOSTIC FUNCTION
1)
Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s is executed properly.
2)
During diagnosis, the following displays are shown.
000
000000
HL85_0100
M
N
O
P
Q
R
M
Firmware :
Version information of microprocessor
In case of file name : HL85 and Version : 0100 indicates[HL85_0100].
N
Time : Total hour of turn the TV on. (Unit : H)
O
Power : Operation number of protecting circuit ----"000" is normal.
When indication is other than "000", overcurrent apt to flow, and circuit parts may possibly be damaged.
P
Bus line : --"OK" is normal
"SCL-GND"(Red indication) : SCL-GND short circuit
"SDA-GND"(Red indication) : SDA-GND short circuit
"SCL-SDA"(Red indication) : SCL-SDA short circuit
Q
Bus cont : --- "OK" is normal.
NG is abnormal(Red indication).
When type name of semiconductor indicates.
R
Block
UV : TV reception mode
V1 : VIDEO 1 input mode
V2 : VIDEO 2 input mode
V3 : ColorStream HD IN
V4 : HDMI A/V IN