C-2
WHEN REPLACING EEPROM (MEMORY) IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
Table 1
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
The unit will now have the correct DATA for the new MEMORY IC.
Enter DATA SET mode by setting VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.
ADDRESS is now selected and should "blink". Using the UP/DOWN button on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press RIGHT/LEFT button to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing RIGHT/LEFT button will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
After the finishing of the initializing of shipping, the unit will turn off automatically.
DF
A2
01
C0
A6
1C
86
B8
42
E4
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
+A
+B
+C
+D
+E
+F
INI
01
1F
24
40
45
5D
62
45
4A
8F
00
00
00
00
00
00
00
00
19
77
05
07
21
10
07
00
22
74
81
8F
40
00
27
0A
2A
00
13
C0
B3
03
0D
36
03
00
00
10
05
67
0F
15
0A
AA
00
20
00
5A
98
33
04
76
30
01
07
06
40
40
40
40
C0
80
35
70
72
99
59
68
5B
00
73
14
1F
2D
24
16
EF
DB
DB
DB
15
00
00
26
06
07
50
99
00
00
00
00
00
F6
60
09
00
C9
C8
E8
BC
80
00
3F
22
22
00
00
00
00
FF
C0
52
50
8B
00
06
06
22
00
11
0A
00
07
00
00
00
B6
01
48
33
39
3C
3F
42
45
48
4B
4E
70
0F
1D
6D
FF
FF
FA
FA
80
96
8B
8C
90
22
00
90
33
23
27
2A
2D
30
A0
36
51
53
55
57
58
59
5A
5C
5D
5E
5F
61
63
65
67
B0
5B
69
6A
6B
6C
6D
6E
6F
71
71
72
72
73
73
74
74
76
76
77
77
77
77
78
78
78
78
15
04
04
FE
E8
F0
FA
27
33
0E
54
---
---
---
---
---
---
---
---
C0
70
75
75
75
75
76
76
D0
79
42
00
00
00
0C
E0
21
32
32
38
00
3F
F0
---
---
---
---
---
---
---
DC
3C
22
22
5A
71
69
33
00
69
33
00
44
00
77
59
94
56
02
100
F1
0E
38
22
22
DA
71
110
01
82
04
03
05
02
02
02
02
02
01
00
81
00
81
81
02
81
02
00
81
05
00
FB
F7
00
00
00
00
00
23
16
F8
08
16
120
02
00
88
00
D0
81
02
130
00
00
7C
3E
00
00
140
00
03
03
---
---
---
ADDRESS
DATA
INIT 000 DF
CRT ON 0010
OEC7111A_073
FIG. 1