ELECTRICAL ADJUSTMENTS
D-4
2-13: TILT
1.
2.
3.
4.
5.
6.
Connect the digital voltmeter between W843 and W844.
Receive the crosshatch signal from the Pattern Genera-
tor.
Press the PIC SIZE button on the remote control to
select the FULL screen mode.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (57) on the remote control to
select "TILT CENT".
Press the VOL. UP/DOWN button on the remote control
until the voltage become minimum(0V).
2-14: Confirmation of Fixed Value (Step No.)
Please check if the fixed values of the each adjustment
items are set correctly referring below.
FUNCTION
V.POSI
V-EHT
H-EHT
V-BLK P
V-BLK S
V.LIMIT
V.CORR
V.S.CORR
S.CORR
CORNER
C.PARA
C.SAW
V.SYMM
R-Y GAIN
R-Y PHASE
G-Y GAIN
G-Y PHASE
BRI.MAX
BRI.MIN
CONT.CENT
CONT.MAX
CONT.MIN
COL.MAX
COL.MIN
SHARP.CENT
SHARP.MAX
SHARP.MIN
TEST STEREO
TEST AUDIO
NO.
03
07
08
09
10
12
13
14
19
20
21
22
23
39
40
41
42
44
45
46
47
48
50
51
54
55
56
58
59
RF
01
05
06
00
00
00
10
45
22
20
07
07
128
15
15
03
00
210
100
65
80
30
100
00
77
127
00
00
00
CS
01
05
06
00
00
00
10
45
22
20
07
07
128
15
15
03
00
210
100
65
80
30
95
00
77
127
00
00
00
AV
01
05
06
00
00
00
10
45
22
20
07
07
128
15
15
03
00
210
100
65
80
30
100
00
77
127
00
00
00
Fig. 2-5
White 100%
115%
DIGITAL
01
05
06
00
00
00
10
45
22
20
07
07
128
15
15
03
00
210
100
65
80
30
100
00
77
127
00
00
00
HD-MI
01
05
06
00
00
00
10
45
22
20
07
07
128
15
15
03
00
210
100
65
80
30
90
00
77
127
00
00
00