– 10 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23
******
POWER : 000
BUS LINE : OK
BUS CONT : OK
BLOCK : UV V1 V2
or QV01 QV01S
SYNC
1
2
3
4
5
1
Part number of microprocessor (QA01)
2
Operation number of protection circuit (current limiter) . . . . “000” is normal.
3
BUS line check
“OK” ................... Normal
“SCL-GND” ........ SCL-GND short circuit
“SDA-GND” ........ SDA-GND short circuit
“SCL-SDA” ......... SCL-SDA short circuit
4
BUS line ACK (acknowledge) check
“OK” ..................... Normal
Display of Location Number . . . . NG
(Display example)
“QA02 NG”, “H001 NG”, “Q501 NG” etc.
Note: The indication of failure place is only one place though failure places are plural. When
repair of a failure place finishes, the next failure place is indicated. (The order of priority of
indication is left side.)
5
Sync. signal check
Green display ..... Normal
Cyan display ...... No check
Red display ........ NG
UV ........... TV mode
V1 ........... VIDEO 1 mode
V2 ........... VIDEO 2 mode
*
The item marked with
are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.
Summary of Contents for 27A60
Page 32: ... 31 32 MAIN BOARD PB9361 BOTTOM FOIL SIDE ...
Page 35: ... 36 GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS MEMO ...
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......