Service Instruction
2004 LCD Television
Page 6 of 12
6. Assembly
6-1. Follow the lamp unit removal instructions in reverse order to re-assemble
the backlight lamp assembly. (Section2-5).
Assembly Cautions
Handle fragile lamp units with extreme caution.
Replace lamp units in a dust-free environment.
Do not bend or pinch flat cables when installing the panel unit.
Ferrite core may be damaged even by a slight shock. Attach ferrite cores
very carefully.
Connect the connectors securely to the INV board.
Connect small connectors
to the INV board (GND
side).
Connect small connectors
to the INV board (HOT
side).
INV board (HOT side)
INV board (GND side)
Panel unit