SERVICE MANUAL
3. High Voltage Inspection
Measure voltages of test points on the main PCB with the digital voltmeter. Measure the CRT high
voltage with the high-voltage testing equipment and heater voltage with the high-frequency
effective voltmeter. The rated values are shown as below.
Table 2
Test Point
Voltage (V)
Negative of VD603
25
±
1.5V (for BSC6OU FBT only)
27
±
1.5V (for BSC62V1 FBT only)
Negative of VD855A
195
±
5.0V
CRT anode
25
±
1.5KV (for IRICO
,
SHANGHAI NOVEL, LG, CHUNGHWA
,
and THAI CRTs)
27
±
1.5KV (SAMSUANG
,
BMCC)
Heater
6.3
±
0.3Vrms
4. Focus
Adjustment
Caution: Dangerously high voltages are present inside the TV. Extreme caution should be
exercised when working on the TV with the back removed.
4.1 After removing the back cover, look for the FBT on the main PCB. There should be a FCB on the
FBT.
4.2 Power on the TV and preheat it for 15 min.
4.3 Receive a normal TV signal. Rotate knob of the FCB until you get a sharp picture.
Before Adjusting After Adjusting
Fig. 4
5. Safety
Inspection
5.1 Inspection for insulation and voltage-resistant
Perform safety test for all naked metal of the TV. Supply high voltage of 3000V AC, 50Hz (limit
current of 10mA) between all naked metal and cold ground. Test every point for 3 sec. and ensure
no arcing and sparking.
9
Summary of Contents for 21E88
Page 25: ...SERVICE MANUAL CONTROL BUTTONS 1 CONTROL BUTTONS Fig Fig 5 Front panel 23 Fig 6 Rear panel ...
Page 36: ...SERVICE MANUAL 3 Block Diagram for TMPA8801 Fig 13 34 ...
Page 37: ...SERVICE MANUAL 4 Block Diagram for TMPA8807 Fig 14 35 ...
Page 51: ...SERVICE MANUAL 3 Block Diagram Fig 22 Block Diagram 49 ...
Page 63: ...CIRCUIT DIAGRAM FOR 21E88 ...
Page 66: ...PRINTED CIRCUIT BOARD DIAGRAM 1 ...
Page 67: ...PRINTED CIRCUIT BOARD DIAGRAMS 2 ...
Page 68: ...PRINTED CIRCUIT BOARD DIAGRAMS 3 JUC7 820 820 ...