5
CIRCUIT PROTECTION
The receiver is protected by a 4.0A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 120V AC using a variac transformer for accurate
input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to P603 Pin3 and make
sure that the voltmeter reads 18.9 ±1.1V.
5. Apply external 24.5V DC at P603 Pin3 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord at least 4
second before plugging in again. Now make sure that
normal picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC
line voltage, with a strong air signal or a properly tuned
in test signal.
3. Enter the service mode and set Y-mute ON by using
Service R/C.
4. The voltage should be approximately 28.6kV (at zero
beam).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
21ARF46
Summary of Contents for 21ARF46
Page 1: ...FILE NO 2006 SERVICE MANUAL COLOR TELEVISION 21ARF46 DOCUMENT CREATED IN JAPAN Feb 2006 ...
Page 12: ...11 MODEL 21ARF45 CHASSIS LAYOUT 21ARF46 ...
Page 13: ...12 MODEL 21ARF46 BLOCK DIAGRAM MAIN Unit 21ARF46 ...
Page 14: ...13 21ARF46 ...
Page 15: ...MODEL 21ARF46 BLOCK DIAGRAM MTS MODULE Unit 21ARF46 14 ...
Page 16: ...15 21ARF46 ...
Page 17: ...16 MODEL 21ARF46 BLOCK DIAGRAM CRT Unit 21ARF46 ...
Page 20: ...6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit 21ARF46 19 ...
Page 21: ...A B C D E F G H 10 9 8 7 6 5 4 3 2 1 SCHEMATIC DIAGRAM MAIN 1 Unit 21ARF46 20 ...
Page 22: ...17 16 19 18 15 14 13 12 11 10 21 21ARF46 ...
Page 23: ...A B C D E F G H 10 9 8 7 6 5 4 3 2 1 SCHEMATIC DIAGRAM MTS Unit 21ARF46 22 ...
Page 26: ...6 5 4 3 2 1 A B C D E F G H PWB B CRT Unit Wiring Side 21ARF46 25 ...
Page 34: ...PACKING OF THE SET 21ARF46 33 ...
Page 35: ...21ARF46 34 ...
Page 37: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...