IC199 memory data
WHEN REPLACING EEPROM (MEMORY) IC
INITIAL
From
T o
Change of MICON IC.
Cause
0A
AA
How to Change memory data
1.
2.
Enter DATA SET mode by setting VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 1 second.
ADDRESS and DATA should appear as FIG 1.
ADDRESS
DATA
INIT 00 50
CRT ON 0010
00
ADDRESS is now selected and should "blink". Using the VOL. UP/DOWN button on the remote,
step through the ADDRESS until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using VOL. UP/DOWN button until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 1 second.
After the finishing of the initializing of shipping, the unit will turn off automatically.
3.
4.
5.
6.
7.
8.
9.
10.
11.
FIG. 1
The unit will now have the correct DATA for the new MEMORY IC.