– 15 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
Item. [BELL] NO ADJUSTMENT
Name. BELL FILTER
SETTING.
Input signal.
Measurement place.
Adjustment method.
Making standard.
Item. [SRY]
Name. SECAM R-Y BLACK LEVEL. SETTING
Input signal. SECAM COLOR BAR.
Measurement place. Q501 #18 (R-out)
Adjustment method. Adjust [SRY] the level of the monochrome signal part must be a match to the level of
horizontal blanking signal.
(Adjust this item after adjust [COLS])
Making standard. 0
±
40mV (p-p)
Item. [SBY]
Name. SECAM B-Y BLACK LEVEL.
SETTING.
Input signal. SECAM COLOR BAR.
Measurement place. Q501 #20 (B-out)
Adjustment method. Adjust [SBY] the level of the monochrome signal part must be a mutch to the level of
horizontal blanking signal.
(Adjust this item after adjust [COLS])
Making standard. 0
±
40mV (p-p)
Item. [COLS]
Name. SUB-COLOR CENTER (SECAM).
SETTING. CHROMA ADJUSTMENT MODE
Input signal. SECAM COLOR BAR.
Measurement place. Q501 #20 (B OUT)
Adjustment method. Adjust the amplitude of B-Y. (Mute the picture in adjustment)
Making standard. 1.75
±
0.2V (0-p)
FOR SECAM MODEL ONLY