– 15 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
RCUT
GCUT
BCUT
GDRV
BDRV
CNTX
BRTC
COLC
TNTC
HPOS
VPOS
HIT
Item
RED CUT-OFF
GREEN CUT-OFF
BLUE CUT-OFF
GREEN DRIVE
BLUE DRIVE
SUB-CONTRAST
SUB-BRIGHTNESS
SUB-COLOR
SUB-TINT
HORIZONRAL POSITION
VERTICAL POSITION
HEIGHT
Name of adjustment
Reference Data
30H
30H
30H
80H
80H
50H
38H
2CH
42H
19H
02H
1EH
✩
✩
✩
✩
✩
✩
✩
✩
✩
✩
✩
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Table-2
CHAPTER 2
SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
✩
These adjustments may be required when replacing QA02 and Q501.
19"
HIGH VOLTAGE AT ZERO BEAM:
(A)
24.7 kV
MAX HIGH VOLTAGE:
(B)
26.1 kV
Table-1
DESIGN MODE
ADJUSTING ITEMS AND DATAS IN THE DESIGN MODE:
Data
Item
Name of adjustment
Preset Data
Remarks
*
There are no adjusting item in the DESIGN MODE.
Table-3
CIRCUIT CHECKS
FBT DETECTION VOLTAGE
(C)
19"
22.03 V
Table-4