C-3
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press RIGHT/LEFT button to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing RIGHT/LEFT button will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn on the POWER.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button
(1)
on the remote control for more than 2 seconds.
After the finishing of the initializing of shipping, the unit will turn off automatically.
FIG. 2
1.
2.
3.
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button
(6)
on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
1.
2.
3.
4.
FIG. 1
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button
(2)
on the remote control for more than 2 seconds.
After the confirmation of each check sum, turn off the power.
CONFIRMATION OF CHECK SUM, POWER ON TOTAL HOURS AND MICON VERSION
Initial total of MEMORY IC, POWER ON total hours and MICON VERSIONcan be checked on the screen. Total hours are
displayed in 16 system of notation.
NOTE:
WHEN REPLACING EEPROM (MEMORY) IC
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
CONFIRMATION OF INITIAL DATA
INIT : 5BFB
VCT-P : 2D59 LCD ON : 0000
EEPROM : W51C01BM00
ANALOG M : DB180_80424A
ANALOG S : DB0F0_70821B
ADDRESS
DATA
INIT
0000 00
LCD ON 0000
ANALOG M : DB180_80424A
ANALOG S : DB0F0_70821B
NOTE: The each item value might be different according to each set.
NOTE: No need to set data other position than 0D00~0E3F and 1900~7FFF
Initial setting data check sum.
SCALER data check sum.
Main Micon check sum.
Sub Micon check sum.
EEPROM version.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)