SPECIFIC INFORMA
TIONS
– 13 –
CHAPTER 2
SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Table-1
Table-2
14"
HIGH VOLTAGE AT ZERO BEAM:
(A)
24.5 kV
MAX HIGH VOLTAGE:
(B)
25.0 kV
AC VOLTAGE
(C)
110-240 V
RCUT
R CUTOFF (B/W)
20H
←
GCUT
G CUTOFF (B/W)
20H
←
BCUT
B CUTOFF (B/W)
20H
←
GDRV
G DRIVE
40H
←
BDRV
B DRIVE
40H
←
BRTC
SUB BRIGHT CEN
40H
←
COLC
SUB COLOR CEN NTSC
30H
←
TNTC
SUB TINT CEN
45H
←
COLP
SUB COLOR CEN PAL
09H
←
COLS
SUB COLOR CEN SECAM
30H
←
SCNT
SUB CONTRAST
08H
←
HPOS
50Hz H-POSITION
0DH
13H
VPOS
V-POSITION
04H
←
HIT
HEIGHT
1EH
24H
VLIN
V-LINEARITY
0AH
←
SBY
SECAM R-Y
08H
←
SRY
SECAM-B-Y
08H
←
RAGC
RF AGC
2AH
←