5. Specification  

Model 

 

 

CSB1100CL-10 

Image sensor 

 

CMOS Image sensor 

    Total pixel 

 

1280 (H) x 1024 (V) 

    Active pixel 

 

1240 (H) x 1023 (V) 

    Pixel size 

 

6.7 (H) x 6.7 (V) micro m 

    Image area 

 

8.308 x 6.854 mm 

    Driving frequency 

33.3333MHz 

Scanning line 

 

1023 lines 

Scanning system   

Progressive 

Flame rate 

 

22.2 fps 

(Under Rolling shutter mode and all pixel’s data read out mode) 

Sync system 

 

Internal 

Aspect ratio 

 

5:4 

Subject illumination 

2600 lx,   F5.6  (3100K) 

(Exposure time: Approx. 16 ms) 

Video output 

 

Camera link (LVDS, 10bit,  Pixel clock 33.3333MHz) 

S/N 

 

 

47 dB (p-p) / rms     

(Exposure time: Approx. 16 ms) 

Control signal 

 

Refer to COMMAND table 

Gamma   

 

1.0 Fixed  

Electronic shutter  

Shutter speed setting by any given timing through Camera Link communication command. 

Shutter mode 

 

Global shutter 

Random Trigger Shutter 

RTS  operation  is  available  by  external  trigger  signal  IN.  Shutter  speed  preset  or  shutter 
speed control by pulse width is available. 

 

 

 

 

 The exposure starts at shutter trigger rising edge and ends at shutter trigger falling edge 
under pulse width control for shutter speed. 

Power source 

DC12V +/- 10% (Source ripple level 100mV(p-p) or less) 

Power consumption 

Approx. 1.4W 

Ambient condition 

Temperature: 

 

 

 

 

 

 

(Performance guaranteed) From 0 through 40 degrees Celsius 

 

 

(Operation guaranteed) From -10 through 50 degrees Celsius 

 

(Preservation) From -20 through 60 degrees Celsius 

 

 

 

Humidity: 

 

 

 

 

 

 

(Performance guaranteed) From 20 through 80 % (No condensing)

   

 

(Operation guaranteed) From 20 through 80 % (No condensing) 

 

(Preservation) From 20 through 95 % or less (No condensing) 

Lens mount 

C-mount  

 

 

 

 

 

 

 

Flange back 

17.526 mm 

External dimension 

44 (W) x 29 (H) x 52 (D) mm 

(Without projection) 

Weight 

Approx. 120 g 

Electro-Magnetic Compatibility 

(1) EMI(Electro-Magnetic Interference) 

EN50081-2(EN55011-A) adaptation 

(2) EMS(Electro-Magnetic Susceptibility) EN61000-6-2 adaptation 

* Please contact our sales person about interface specification. 

Summary of Contents for CSB1100CL-10

Page 1: ...T SPECIFICATION Contents Before use General safety instructions 1 Product Description 1 2 Features 1 3 Configuration 1 4 Optional parts 1 5 Specifications 2 6 Connection 3 7 DIP Switch setting 4 8 Functions 5 9 Timing Chart 8 10 COMMAND table 9 11 External View 10 ...

Page 2: ...n below Notes 1 Personal injury means wounds burns electric shocks and others for which hospitalization or long term care are not required 2 Material damage means any direct or consequential damage related to property or material loss WARNING This mark warns the user that improper use may cause death or severe personal injury of the user or people in the vicinity CAUTION This mark warns the user t...

Page 3: ... apart Do not disassemble repair or modify the equipment Otherwise fire or electric shock may result For internal repair inspection or cleaning contact your sales representative Avoid Do not place anything on the equipment If metallic objects liquid or other foreign matter enters the equipment fire or electric shock may result Avoid Do not install the equipment in an unstable or inclined location ...

Page 4: ...ations exposed to direct sunlight or humidity Otherwise the internal temperature of the equipment will rise which may cause a fire Avoid Use only specified DC power cables and connection cables Otherwise fire or electric shock may result Avoid When performing connection turn off power When connecting the power cable or connection cable turn off the equipment power Otherwise fire or electric shock ...

Page 5: ...ments give consideration to safety measures and inform us of such usage 1 Use of the equipment in the conditions or environment contrary to those specified or use outdoors 2 Use of the equipment in applications expected to cause potential hazard to people or property which require special safety measures to be adopted This product can be used under diverse operating conditions Determination of app...

Page 6: ... the camera to protect the image pickup surface If the equipment is not to be used for a long duration Turn off power to the camera for safety Maintenance Turn off power to the equipment and wipe it with a dry cloth If it becomes severely contaminated gently wipe the affected areas with a soft cloth dampened with diluted neutral detergent Never use alcohol benzene thinner or other chemicals becaus...

Page 7: ...esses user defined areas only are read out 5 High dynamic range This model features a high dynamic range with multi slope integration mode both high and low intensity subjects can be captured at the same time despite the high difference in contrast 6 SUBSAMPLING Readout of active pixels is lowered enabling increased frame rates This mode suitable for image orientation and confirmation 3 Configurat...

Page 8: ...gger signal IN Shutter speed preset or shutter speed control by pulse width is available The exposure starts at shutter trigger rising edge and ends at shutter trigger falling edge under pulse width control for shutter speed Power source DC12V 10 Source ripple level 100mV p p or less Power consumption Approx 1 4W Ambient condition Temperature Performance guaranteed From 0 through 40 degrees Celsiu...

Page 9: ...able side 10126 6000 Manufactured by 3M PIN Signal Name I O PIN Signal Name I O 1 GND 14 GND 2 TX OUT 0 OUT 15 TX OUT 0 OUT 3 TX OUT 1 OUT 16 TX OUT 1 OUT 4 TX OUT 2 OUT 17 TX OUT 2 OUT 5 TX CLK OUT OUT 18 TX CLK OUT OUT 6 TX OUT 3 OUT 19 TX OUT 3 OUT 7 Ser TC RxD IN 20 Ser TC RxD IN 8 Ser TFG TxD OUT 21 Ser TFG TxD OUT 9 Trig IN 22 Trig IN 10 EXT AFR IN 23 EXT AFR IN 11 EXT SP IN 24 EXT SP IN 12 ...

Page 10: ...1 Baud rate setting Baud rate setting of camera IN OUT 1 2 Baud rate OFF OFF 9600 ON OFF 19200 OFF ON 38400 2 Starting status setting Designate the memory page readout in starting up of a camera 3 4 Memory OFF OFF 1 ON OFF 2 OFF ON 3 ON ON 4 OFF Rear DIP switch 1 2 3 4 Baud rate selection Starting status setting ON ...

Page 11: ...ternal resister setting value Random trigger shutter function is available only under global shutter mode 3 Sub sampling Horizontal and vertical thinning out reading is performed at every 1 line 3 types of settings are available 1 2 horizontal only 1 2 vertical only and 1 2 both This function can read out the full image at high speed while its resolution is deteriorated The combined use with WOI c...

Page 12: ...nt is available up to 16 windows in all active pixel area The setting of readout address is available up to 8 types User can reprogram all setting types from 1 through 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 5 1 2 3 4 6 7 8 ...

Page 13: ...A the next area designated by X3 Y3 and X4 Y4 is read out block B in the left figure Block A Block B 1 2 3 4 5 6 7 9 11 13 15 8 10 12 14 16 17 18 19 20 X1 Y1 X2 Y2 X3 Y3 X4 Y4 In the case of more than two readout areas which both comprise the same readout lines The designated areas are read out in order of address from the start X1 Y1 to the end X4 Y4 Block A Block B 1 2 3 4 5 6 7 8 9 10 11 12 X1 ...

Page 14: ...d image A image B FRAME CAMERA INTERNAL VIDEO DATA CAMERA OUTPUT EXPOSURE CAMERA INTERNAL Integrate time Depends on register setting Approx 15 66us Approx 13 38us 43 7ms 43 73ms Exposure time image A image B FRAME CAMERA INTERNAL VIDEO DATA CAMERA OUTPUT EXPOSURE CAMERA INTERNAL Integrate time no reaction Approx 15 66us Approx 13 38us 43 7ms 43 73ms Exposure time TRIG EXTERNAL Approx 28us Depends ...

Page 15: ...Setting value readout Setting value storage Resset Video OUT bit width Sub Sampling Vendor name Model name Other Window Memory Shutter Trigger Multi slope image A image B FRAME CAMERA INTERNAL VIDEO DATA CAMERA OUTPUT EXPOSURE CAMERA INTERNAL Integrate time no reaction Approx 15 66us Approx 13 38us 43 7ms 43 73ms Exposure time TRIG EXTERNAL Approx 28us Approx 300ns Trigger disable time Trigger dis...

Page 16: ...10 D4134040A 11 External View ...

Reviews: