114 / 177
Copyright © 2018 - 2020 Toshiba Teli Corporation, All rights reserved.
https://www.toshiba-teli.co.jp/en/
DAA00195C
TimerControl
This section describes TimerControl features.
This camera series is able to generate Timer0Active signal beginning from trigger or exposure start signal.
This signal can be used as strobe control signal.
TRIG_IN
(Line0)
Exposure
TIMER0 ACTIVE
Delay
Duration
※
ActiveLow
EXPOSURE ACTIVE
Trigger
(Frame Start Trigger)
TriggerDelay
TimerTriggerSource = Line0Active
TimerTriggerSource = ExposureStart
TimerTriggerSource = FrameTrigger
Timer0Active