123 / 160
Copyright © 2016-2018 TOSHIBA TELI CORPORATION, All Rights Reserved.
http://www.toshiba-teli.co.jp/en/index.htm
D4259344C
ALCControl
This section describes ALCControl feature.
This camera series provides some registers to adjust the various parameter of ALC operation.
-
ALCPhotometricAreaSize defines photometric area size for measuring luminance.
100% (H:100% x V:100%)
64% (H:80% x V:80%)
16% (H:40% x V:40%)
ALCPhotometricAreaSize (e.g. 100%, 80%, 40%)
-
ALCExposureValue defines a correction value for a convergence value.
Final convergence value is determined by the following formula.
ALCExposureValue
Final convergence value
= 84(
Reference Luminance)
× 2