background image

The front panel power switch is also

a circuit breaker. As a circuit breaker,

it prevents excessive current from

entering the PIU.

When the power is on, the Switch is

illuminated. When the breaker trips,

the

switch

returns

to

its

“off”

position.

Front Panel Layout

Circuit Protection

Torus PIUs will shut-down if internal

unit temperature reaches excessive

levels.

Thermal Protection

Electrical Specifications

Input Voltage

Nominal

Selectable 240VAC

(2 x 120VAC, balanced)

or 208VAC.

Factory wired for 240VAC 60Hz

Range +/- 10% voltage

57-63Hz

120VAC, 60Hz

Range +/- 10% voltage

57-63Hz

Model Number

RM 20 BAL RK

RM 20 BAL CB

RM 20 BAL CS

RM 20 RK

RM 20 CB

RM 20 CS

Input

Current

Limiting

10A

Circuit Breaker

Front Panel

20A

Circuit Breaker

Front Panel

Input Current

Rating

(see note above)

10A

16A

½ cycle

100A

400A

Load Current Capability

1 second

80A

200A

10 seconds

30A

100A

Per CSA code, devices with line

cords and plugs must not consume

more than 80% of a branch

circuit’s rating.

While Torus Power Isolation Units

are designed to handle well beyond

these limits, they must be marked

with a maximum input current that

satisfies the requirements.

Input Current Rating

19” Pro Series Rack Mount Faceplate

Balanced 20A Model Number RM 20 BAL RK

Single 20A Model Number RM 20 RK

ON/OFF Switch / Circuit Breaker

17” Consumer Series Faceplate

Balanced 20A Model Numbers RM 20 BAL CB and RM 20 BAL CS

Single 20A Model Numbers RM 20 CB and RM 20 CS

www.TorusPower.com

Owner’s Manual

Audio / Video Power Isolation Units

Rack Mount / Consumer

03/12

Power Conditioners

REV.03/01/2012

Reviews: