For a
Normally-Open
sensor type, attach the
Yellow
wire to the remaining Sensor terminal.
Tape back the Brown wire. See Figure 3.
4. Attach the two
Red
wires to the 24 Vac
terminals in either order.
Important: Most controllers equipped
for sensor connection provide a switch to
control the sensor circuit. Check the
switch setting to ensure that it is not in
the Bypass or Off position.
Wiring Procedure II (no Sensor terminals)
1. Locate the valve common wire terminal,
generally labeled “C” or “COM”, and remove
the attached common wire(s).
2. Attach the
White
wire to this terminal.
3. Splice the
Brown
wire to the common
wire(s) using a wire nut or electrical tape.
Tape back the Yellow wire. See Figure 4.
4. Attach the
Red
wires to the 24 Vac terminals.