Adjusting the Self-Propel
Drive
Whenever you install a new self-propel cable or if
the self-propel drive is out of adjustment, adjust the
self-propel drive.
1.
Turn the adjustment knob counterclockwise to
loosen the cable adjustment (
).
g027231
Figure 37
1.
Handle (left side)
4.
Turn the knob clockwise to
tighten the adjustment.
2.
Adjustment knob
5.
Turn the knob
counterclockwise to
loosen the adjustment.
3.
Self-propel-drive cable
2.
Adjust the tension on the cable (
) by
pulling it back or pushing it forward and holding
that position.
Note:
Push the cable toward the engine to
increase the traction; pull the cable away from
the engine to decrease the traction.
3.
Turn the adjustment knob clockwise to tighten
the cable adjustment.
Note:
Tighten the knob firmly by hand.
Servicing the Blade-Drive
System
Service Interval:
Every 50 hours
1.
Remove the blade-drive system cover (
g016491
Figure 38
1.
Bolts
2.
Cover
2.
Brush or blow out debris from the inside of the
shield and around all the parts.
3.
Hold a 0.25 mm (0.010 inch) feeler gauge, a
piece of paper, or a note card against the wall
and slide it down behind the belt tension spring.
Note:
If there is a visible gap between the
gauge and the spring, tighten the adjusting bolt
and the nut until the paper barely slides freely in
and out of the gap (
g017221
Figure 39
1.
Belt-tension spring
4.
Adjusting nut
2.
Adjusting bolt
5.
Blade-drive belt
3.
Gap
6.
Wall
Important:
Do not overtighten the adjusting
bolt. This could damage the blade-drive belt.
23