1. Raise the seat to gain access to the fuse holder
2. To replace a fuse, pull out on the fuse to remove it
G005893
1
Figure 46
1.
Relays
5.
Fuse block
2.
Alarm
6.
Main-30 amp
3.
Positive battery cable
7.
Charge circuit-25 amp
4.
Battery
8.
Open slots
Drive System
Maintenance
Checking the Tire Pressure
Service Interval:
Every 25 hours
Maintain the air pressure in the front and rear tires
as specified. Uneven tire pressure can cause uneven
cut. Check the pressure at the valve stem after every
50 operating hours or monthly, whichever occurs first
(Figure 47). Check the tires when they are cold to get
the most accurate pressure reading.
Rear Tires: 13 psi (90 kPa)
Front Tires (castor wheels): 35 psi (139 kPa)