Network VP Sensor Input Kit (SIK)

Installation Instructions

Sensor Input Board Overview

Temperature LED

Indicates if a temperature 

sensor is present.

Transmit LED

Indicates data packet  

is being sent.

IN1 LED - Pressure

Indicates if a pressure sensor  

is present.

Temperature Probe Connector

Connector for temperature 

sensor probe.

Power Distribution Connector

Receives 5V and 9V to 

power the Sensor Input 

Board.

5V LED

Indicates 5V is active.

24V LED

Indicates 24V is active.

12V LED

Indicates 12V is active.

24V Connections

Connection to receive 24V 

AC from satellite.

IN2-IN6 LEDs

Indicate sensor activity for 

channels IN2-IN6.

IN 1

IN 2

IN 3

IN 4

IN 5

IN 6

COM

12V

Terminals

Terminal Description

IN 1

Pressure Sensor Input

IN 2

Flow, Rain, or Status Sensor Input

IN 3

Flow, Rain, or Status Sensor Input

IN 4

Flow, Rain, or Status Sensor Input

IN 5

Flow, Rain, or Status Sensor Input

IN 6

Flow, Rain, or Status Sensor Input

COM

12 V Ground or Common

12V

12 V DC Output

The Sensor Input Kit receives sensor data from status, flow, temperature, rain buckets, and 

pressure sensors, then relays that data to the Lynx computer. There, it can be used to monitor 

conditions and automatically respond to user-defined alarms.
•  Sensor data is stored in the VP satellite for 12 hours and transmitted back to Lynx  

every 2 hours.

•  Current sensor information and alarm status can be viewed in the VP faceplate.
•  Central-based or stand-alone alarm responses can be configured for any sensor input.

Kit Components

•  Sensor Input Board

•  Surge Board

•  Mounting hardware

•  Fuse

•  Cables

Summary of Contents for SIK

Page 1: ...als Terminal Description IN 1 Pressure Sensor Input IN 2 Flow Rain or Status Sensor Input IN 3 Flow Rain or Status Sensor Input IN 4 Flow Rain or Status Sensor Input IN 5 Flow Rain or Status Sensor Input IN 6 Flow Rain or Status Sensor Input COM 12 V Ground or Common 12V 12 V DC Output The Sensor Input Kit receives sensor data from status flow temperature rain buckets and pressure sensors then rel...

Page 2: ...the satellite controller and check for proper operation 3 2 1 4 Figure 1 5 A B 6 Timing Module sold separately Installation The Sensor Input Board only works with the new Timing Module TM right included with the sensor input board bundle VP SEN BUNDLE or purchased separately 118 5487SK If your controller still uses the old TM you must purchase the new TM to take advantage of the VP Sensor Input Ki...

Page 3: ...tem and cables already run to the controller For all sensor installation procedures turn off or remove power from the controller Pressure Sensor Toro sells a pressure sensor kit part number PRESS200 SEN KIT composed of a 6 long sensor cable and a pressure sensor Steps 1 At the sensor terminal board secure the pressure sensor s black lead to screw IN 1 and white lead to screw 12V see Terminals Expl...

Page 4: ...ermitted for operation Max Maximum pressure permitted for operation Unit Select English or Metric for display of pressure in pounds per square inch psi or bar Alarm Select either a high limit alarm Hi and or a low limit alarm Lo In the Set field it is possible to turn the Hi and Lo alarm On of Off QTime Qualification time How long does the alarm condition max pressure exceeded for example have to ...

Page 5: ...Set a time when irrigation is no longer permitted I_Min For standalone Minimum flow rate allowed at the beginning of the water window I_Max Paired with I_Min Maximum flow rate allowed during the water window O_Max Maximum flow rate allowed outside of water window One might typically set this value rather low to help detect valve or sprinkler leaks Unit Select either English or Metric for display o...

Page 6: ...ber of days Count The number of times the rain bucket has filled and tipped independent of Alarm status and R_Win setting Hr Possible to go back in hour increments to review the number of tips during that hour from the current time H_Cnt The number of tips in that hour Total The number of times the rain bucket has filled and tipped in the rain window R_win above only when the alarm is set to On St...

Page 7: ...n 2 Down arrow to Reset SIB s 3 to change to Yes All 4 There is a confirmation screen Press the Stop button to cancel the reset Firmware Update A handful of satellites will need a firmware update to take advantage of the Lynx Smart Satellite Sensor Kit Check your satellite s firmware 1 Press the Diagnostic button 2 Turn the Command dial to Revision 3 Check Revision number If firmware revision is l...

Page 8: ...h type of sensor installed with minimum and maximum values set 5 Remember a sensor input board takes up 8 stations We have to tell Lynx that the correct satellite from step 2 now has 8 fewer stations Click on Control System find the desired satellite and enter the correct number of stations Figure 2 6 Click Alarm Response to set up alarm conditions for the various sensors 7 Select the desired sens...

Page 9: ... Sensor Input Board to monitor You will see a screen similar to Figure 4 though the number and type of sensors might be different as well as the ranges for the sensors Historic Click Report Generator then Sensors Select the desired sensor the date range and whether to view the sensor data as a table Figure 5 or graph Figure 6 Figure 4 Figure 5 Figure 6 ...

Page 10: ... that may cause undesirable operation This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruction may cause interference to radio and television reception It has been type tested and found to comply with the limits for a FCC Class B computing device in accordance with the specification in subpart J...

Reviews: