Toro R Series Installation And Adjustment Manual Download Page 4

  Front Nozzle Performance Charts 

  Back Nozzle Performance Charts

855RB-5154 Performance Chart

855RB-5558 Performance Chart

Front 

Nozzle 

Positions

Nozzle Set 51 

(Yellow)

Nozzle Set 52 

(Blue)

Nozzle Set 53 

(Brown)

Nozzle Set 54 

(Orange)

Nozzle Set 55

 (Green)

Nozzle Set 56 

(Gray)

Nozzle Set 57 

(Black)

Nozzle Set 58 

(Red)

102-4587

102-4588

102-4589

102-0728

102-0729

102-0730

102-4261

102-4260

Blue

Gray

Red

Gray

Orange

Gray

Orange

Gray

Blue

Gray

Blue

Gray

Orange

Gray

Blue

Gray

102-2925 102-2910 102-2928 102-2910 102-2926 102-2910 102-2926 102-2910

102-2925 102-2910 102-2925 102-2910 102-2926 102-2910 102-2925 102-2910

Back 

Nozzle 

Positions

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

102-4335

102-4335

102-4335

102-4335

102-4335

102-4335

102-4335

102-4335

PSI

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

60

55

16.1

63

20.3

69

23.4

75

31.3

70

56

17.4

66

21.8

70

25.3

76

33.8

80

57

18.5

68

23.3

72

27.0

77

36.0

80

39.1

85

41.0

88

45.4

92

49.7

90

58

19.4

70

24.5

75

28.5

79

38.1

83

41.5

87

43.5

91

48.2

94

52.8

100

59

20.5

72

25.9

76

30.0

80

40.2

86

43.7

90

45.7

94

50.6

96

55.3

Stator

102-1939 Yellow

102-1940 White

Conver.

855RB-5154

855RB-5558

DT54RB-5154 Performance Chart

DT54RB-5558 Performance Chart

Front 

Nozzle 

Positions

Nozzle Set 51 

(Yellow)

Nozzle Set 52 

(Blue)

Nozzle Set 53 

(Brown)

Nozzle Set 54 

(Orange)

Nozzle Set 55

 (Green)

Nozzle Set 56 

(Gray)

Nozzle Set 57 

(Black)

Nozzle Set 58 

(Red)

102-0725

102-7001

102-0727

102-7002

102-6908

102-0730

102-4261

102-4260

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Brown

Red Plug

Brown

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335

102-4335 102-4335 102-4335 102-4335 102-4335 102-6883 102-4335 102-6883

Back 

Nozzle 

Positions

Yellow

Blue

Yellow

Orange

Yellow

Red

Yellow

Beige

Yellow

Beige

Yellow

Red

Yellow

Gray

Yellow

Gray

102-6937 102-2925 102-6937 102-2926 102-6937 102-2928 102-6937 102-2929

102-6937 102-2929 102-6937 102-2928 102-6937 102-4965 102-6937 102-4965

PSI

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

60

59

14.6

62

17.4

68

24.3

71

28.2

70

60

15.7

63

18.8

70

26.3

75

30.6

80

61

16.4

64

20.0

72

27.6

78

32.6

83

39.5

85

42.7

87

45.9

91

50.2

90

62

17.8

66

21.3

74

29.9

80

34.7

85

41.6

88

44.9

90

48.5

93

52.8

100

63

18.1

67

23.6

75

30.4

81

36.7

87

43.7

90

46.8

93

51.2

95

55.4

Stator

102-6929 Blue

102-1940 White

Conver.

DT54RB-5154

DT54RB-5558

   

 Not recommended at these pressures.  Radius shown in feet.  

Toro recommends the use of a 1

1

4

" swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.

Actual site conditions must be considered when selecting the appropriate nozzle.

DT55RB-5154 Performance Chart

DT55RB-5558 Performance Chart

Front 

Nozzle 

Positions

Nozzle Set 51 

(Yellow)

Nozzle Set 52 

(Blue)

Nozzle Set 53 

(Brown)

Nozzle Set 54 

(Orange)

Nozzle Set 55

 (Green)

Nozzle Set 56 

(Gray)

5Nozzle Set 57 

(Black)

Nozzle Set 58 

(Red)

102-6906

102-0726

102-6907

102-0728

102-6955

102-6935

102-6936

102-6909

Yellow

Brown

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Green

Green

Green

Green

Green

Green

Green

102-5670 102-5671 102-5670 102-6884 102-5670 102-6884 102-5670 102-6884 102-5670 102-6885 102-6531 102-6885 102-6531 102-6885 102-6531 102-6885

Back 

Nozzle 

Positions

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

Red Plug

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335

PSI

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

rad/ft

gpm

60

56

15.2

57

20.1

66

24.3

68

28.0

70

58

16.5

60

21.7

67

26.2

71

30.4

80

59

17.5

62

23.1

68

27.8

72

31.7

76

39.7

80

43.1

83

48.2

85

53.0

90

60

18.4

64

24.5

71

28.8

74

34.5

78

43.1

81

45.1

86

51.2

87

56.0

100

61

19.3

66

25.3

72

30.3

75

36.5

80

45.5

82

49.0

90

54.5

89

59.0

Stator

102-1939 Yellow

102-1940 White

Conver.

DT55RB-5154

DT55RB-5558

Nozzles

65 PSI

80 PSI

Part #

Description

Color

Radius

GPM

Radius GPM Profile

Nozzles

65 PSI

80 PSI

Part #

Description

Color

Radius

GPM

Radius GPM Profile

102-6937

Inner Nozzle 

w/ Yellow Restrictor

Yel/Yel

29

3.7

30

4.1

102-6531

Inner Nozzle 

w/ White Restrictor

Grn/Wht

31

4.3

33

4.6

102-6883

Intermediate Nozzle

Brown

38

2.8

38

2.8

102-6884

Intermediate Nozzle

Yellow

41

4.1

43

4.5

102-6885

Intermediate Nozzle

Green

42

5.4

45

6.0

102-2925

Intermediate Nozzle

Blue

40

2.8

42

3.2

102-2926

Intermediate Nozzle

Orange

44

4.3

45

4.8

102-2927

Intermediate Nozzle

Gray

46

5.1

47

5.4

102-2928

Intermediate Nozzle

Red

48

6.5

50

7.0

102-2929

Intermediate Nozzle

Beige

51

8.1

53

9.1

© 2011 The Toro Company • Irrigation Division  • www.toro.com 

 Form Number 373-0581 Rev. A

Summary of Contents for R Series

Page 1: ...an over the top of the sprinkler When performing arc spray adjustment procedures during operation never come in full contact with spray Failure to comply can result in serious injury R Series Sprinkler Conversion Assembly Installation and Adjustment Guide 1 Insert a small screwdriver blade through the slot provided in the sprinkler assembly retaining ring Pry the end of the ring out of the body th...

Page 2: ...Figure 9 Caution Never attempt to turn the ratcheting riser assembly during operation Forcing the riser assembly to turn can result in severe sprinkler damage 4 Rotate the nozzle turret clockwise to the right travel limit See Figure 10 5 Squeeze and hold the arc adjust band at the ribbed section Rotate the nozzle turret in either direction to the desired right limit then release pressure on adjust...

Page 3: ...ndicator tab to the 15 or 25 trajectory position as shown in Figure 13 3 Reinstall the cap For 855RB series A 5 16 nut driver p n 995 105 is required for this procedure 1 Turn the trajectory adjustor left to increase or right to decrease angle See Figure 13 Main Nozzle Diffusion Adjustment optional A 3 32 hex driver P N 995 82 is required for this procedure 1 Move the diffusion screw from its stor...

Page 4: ...7 85 41 6 88 44 9 90 48 5 93 52 8 100 63 18 1 67 23 6 75 30 4 81 36 7 87 43 7 90 46 8 93 51 2 95 55 4 Stator 102 6929 Blue 102 1940 White Conver DT54RB 5154 DT54RB 5558 Not recommended at these pressures Radius shown in feet Toro recommends the use of a 11 4 swing joint at flows over 25 GPM 95 LPM Sprinkler radius data collected in Toro s zero wind test facility per ASAE standard S398 1 Actual sit...