Electrical System
Maintenance
Important:
Before welding on the machine,
disconnect the controller and the negative
cable from the battery to prevent damage to the
electrical system.
Electrical System Safety
•
Disconnect the battery before repairing the
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
•
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.
Replacing the Fuses
Engine
A 15 A in-line fuse is incorporated into the engine wire
harness (
g020717
Figure 24
1.
Fuse
Receiver
An fuse block is incorporated into the receiver wire
harness. It is located behind the receiver on the right
side the of control tower (
).
g029821
Figure 25
1.
Fuse