g028228
Figure 48
1.
Open
3.
Intermediate position
2.
Closed (0)
Calibrating the
Agitation-Bypass Valve
Service Interval:
Yearly—Calibrate the
agitation-bypass valve.
Important:
If you have the ExcelaRate
™
™
™
Spray
System installed turn the selection switch to
M
ANUAL
mode.
1.
Select an open, flat area to perform this
procedure.
2.
Fill the spray tank half full with clean water.
3.
Verify that the agitation-control valve is open.
Note:
If it has been adjusted, open it completely
at this time.
4.
Set the parking brake and start the engine.
5.
Set the pump switch and the agitation switch to
the O
N
position.
6.
Turn the master-boom switch to the O
FF
position.
7.
Move the throttle lever to the F
AST
position.
8.
Use the application-rate switch to adjust the
sprayer-system pressure to 689 kPa (100 psi).
9.
Turn the agitation switch to the O
FF
position and
read the pressure gauge.
•
If the pressure gauge indicates 689 kPa (100
psi), the agitation-bypass valve is properly
calibrated.
•
If the pressure gauge indicates differently,
continue to the next step.
10.
Adjust the agitation-bypass valve (
)
on the backside of the agitation valve until the
sprayer system pressure indicated on the gauge
indicates 689 kPa (100 psi).
g032532
Figure 49
1.
Actuator (agitation valve)
2.
Agitation-bypass valve
11.
Turn the pump switch to the O
FF
position.
12.
Move the throttle lever to the I
DLE
/S
LOW
position
and turn the key switch to the O
FF
position.
Locating the Pump
The pump is located near the back of the tank on the
left side (
).
g028157
Figure 50
1.
Pump
2.
Grease fitting
45