![Toro LT3340 Operator'S Manual Download Page 51](http://html1.mh-extra.com/html/toro/lt3340/lt3340_operators-manual_1131935051.webp)
g330219
Figure 66
1.
Expansion tank
2.
If the coolant level is low, remove the
expansion-tank cap and replenish the system.
Do not overfill.
3.
Install the expansion-tank cap.
Belt Maintenance
Servicing the Alternator
Belt
Service Interval:
After the first 50 hours
Every 250 hours
1.
Apply 10 kgf (22 lb) of force against the alternator
belt (
), midway between the pulleys.
Note:
The belt should deflect 10 mm (3/8 inch).
g295237
Figure 67
1.
Tension bracket bolt
4.
Alternator pivot bolt
2.
Alternator tension bolt
5.
Alternator
3.
Belt
2.
If the belt tension is incorrect, perform the
following:
•
If belt deflection is less than 10 mm (3/8
inch), loosen the alternator pivot bolt and
tension bolt (
), and reduce the belt
tension.
•
If belt deflection is greater than 10 mm (3/8
inch), loosen the alternator pivot bolt and
tension bolt (
), and increase the
belt tension.
Note:
If needed, loosen the tension bracket
bolt (
).
3.
Tighten the bolts (
).
4.
Check the deflection of the belt again to ensure
correct belt tension.
51