background image

IV. Manual Operation

Manual Program Cycle

Use this feature to manually start your normal program cycle at any time. Each valve’s run
time will be operated for the program selected. For example, this can be used to start a
program an extra time on a particularly hot day.

1.

Set the dial to the 

Manual Program Cycle

position.

2.

Select program 

A

B

, or 

C

3.

Press the 

+

button to select 

Manual Program Cycle

watering.

4.

Press the 

Next

button until the desired starting valve is displayed. That valve and all

subsequent valves in the selected program will water in sequence.

5.

Turn the dial to 

Run

position. The timer will complete the manual watering cycle and then

revert to automatic operation.

6.

The display will periodically show the valve number and will count down the run time for
each active valve.

7.

If desired, you may turn the dial to the 

Off

position for longer than three seconds to

discontinue manual watering. Always return dial to the 

Run

position to enable automatic

watering.

10

Summary of Contents for LawnMaster 53603

Page 1: ...Model 53603 Owner s Manual Espa ol P 19 Fran ais P 39...

Page 2: ...e 4 Setting Valve Run Time 5 Selecting Program Start Times 6 Canceling a Program Start Time 7 Selecting Days to Water 7 8 Run Off Positions 9 IV Manual Operation 10 11 Manual Program Cycle 10 Manual V...

Page 3: ...n in pencil on the back of the Quick Reference Card located on the inside of the timer door The REVIEW feature can be used to review your programmed watering plan For the days you have selected in pro...

Page 4: ...oximately 1 8 3 2mm exposed Use a plastic anchor sleeve if wall is plaster board or masonry 3 Mount the hanger kit to the top back of the timer Hang the timer on the mounting screw 4 Drive two additio...

Page 5: ...xceed 0 25 amps maximum output holding current Also if using more than one timer do not share common wires Run a separate common wire for each timer Connecting a Pump Start Relay Note When a pump is t...

Page 6: ...the Next button and the Minutes will flash Press the or button to change the minutes shown on the display Press the Next button and AM PM will flash Press either the or button to change AM PM 3 Month...

Page 7: ...s 8 Set the watering time to under 1 minute or over 9 hours and 59 minutes to set the valve in OFF mode Return dial to Run position Master Valve Pump Start A master valve or pump start is sometimes us...

Page 8: ...me position The display will flash START A1 START B1 or START C1 depending on the position of the program select switch and then show the start time programmed If there is no start time entered OFF wi...

Page 9: ...ram details are retained Because there are no start times there will be no watering with that program This is a convenient way to stop one program without turning the dial to the OFF position in case...

Page 10: ...the Next button to go to Skip Days 7 Press the or button to select the number of days to skip before each watering day Selecting Specific Days of the Week This option allows you to water on specific...

Page 11: ...tion is also used to terminate any running programs whether manual or automatic allow 3 seconds to turn off For immediate shut down turn to Off and push the button 1 Set the dial to the Off position 2...

Page 12: ...Cycle watering 4 Press the Next button until the desired starting valve is displayed That valve and all subsequent valves in the selected program will water in sequence 5 Turn the dial to Run positio...

Page 13: ...ting Step 2 for the remaining valves 4 If using a master valve or pump press the Next button until MASTER is displayed after last valve Press the button This opens the master valve while the other val...

Page 14: ...an 100 results in more watering 00 turns the timer to OFF Example Normal Seasonal Adjustment Program Adj Time Valve 1 Adj Time Valve 1 A 100 10 min 50 5 min B 100 10 min 170 17 min C 100 10 min 200 20...

Page 15: ...ctive watering days By moving the program selector switch each program can be reviewed in turn You can press and hold the button to speed up the review and the button to slow down the review Erase Pro...

Page 16: ...should be Sensor N for Off Setting Sensor Option 1 Set the dial to Special Features position 2 Press the Next button twice The display will show Sensor N 3 Press the button to activate the rain sensor...

Page 17: ...sumes Circuit Protection Lawn Master electronics are protected from electrical disturbances such as large transient voltages and static discharge Electronic Fuse Lawn Master is protected with an elect...

Page 18: ...al bleed closure 3 Disconnect wire to valve If still on valve is bad 4 Check for manual mode place timer in OFF Position 5 Check solenoids for obstructions or wiring shorts 6 Check valve for rocks or...

Page 19: ...ormed in any manner contrary to Toro s specifications and instructions nor where equipment is altered or modified NEITHER THE TORO COMPANY NOR TORO WARRANTY COMPANY IS LIABLE FOR INDIRECT INCIDENT AL...

Page 20: ...raged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equi...

Reviews: