Battery Hydrometer
g033640
Figure 139
Use the battery hydrometer when measuring the specific gravity of the battery
electrolyte. You can get this tool locally.
Dielectric Gel
g033639
Figure 140
Use the dielectric gel to prevent corrosion of unsealed connection terminals. To
ensure complete coating of the terminals, liberally apply the gel to the component
and wire harness connector, plug the connector into the component, unplug
the connector, apply the gel to both surfaces again, and connect the harness
connector to the component again. The connectors must be fully packed with
gel for effective results.
Note:
Do not use the dielectric gel on the sealed connection terminals as the
gel can unseat the connector seals during assembly.
Toro Part No. 107-0342
Electrical System: Special Tools
Page 5–10
Groundsmaster 7210
16222SL Rev C
Summary of Contents for Groundsmaster 7210
Page 4: ...NOTES Revision History Page 4 Groundsmaster 7210 16222SL Rev C...
Page 32: ...Specifications and Maintenance Special Tools Page 2 16 Groundsmaster 7210 16222SL Rev C...
Page 60: ...Diesel Engine Service and Repairs Page 3 28 Groundsmaster 7210 16222SL Rev C...
Page 196: ...Hydraulic System Service and Repairs Page 4 136 Groundsmaster 7210 16222SL Rev C...
Page 304: ...Chassis Service and Repairs Page 6 42 Groundsmaster 7210 16222SL Rev C...
Page 327: ...Drawing 105 7260 Rev E Sheet 1 16222SL Rev C Page A 3 Hydraulic Schematic g186843...
Page 328: ...Page A 4 16222SL Rev C Drawing 119 4372 Rev C Sheet 1 Electrical Schematic Platform g186842...
Page 329: ...Drawing 119 4377 Rev C Sheet 1 16222SL Rev C Page A 5 Electrical Schematic Engine g186841...
Page 336: ...Page A 12 16222SL Rev C Drawing 119 4386 Rev A Sheet 1 Wire Harness Drawing Cab Power g186851...
Page 342: ......