![Toro Groundsmaster 4500-D Service Manual Download Page 73](http://html.mh-extra.com/html/toro/groundsmaster-4500-d/groundsmaster-4500-d_service-manual_1131484073.webp)
Groundsmaster 4500--D/4700--D
Hydraulic System (Rev. A)
Page 4 -- 35
Procedure for Cutting Deck Manifold Relief
Pressure Test
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for approximately 10
minutes. Make sure the hydraulic tank is full.
2. Park machine on a level surface with the cutting units
lowered and off. Make sure engine is off and the parking
brake is engaged.
CAUTION
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS, and Pre-
cautions for Hydraulic Testing at the beginning
of this section.
3. Determine deck manifold relief to be tested. Discon-
nect the inlet hydraulic hose to the appropriate deck mo-
tor (Fig. 32):
A. For pump section (P1), deck manifold relief is
tested at the inlet to the motor on deck #5.
B. For pump section (P2), deck manifold relief is
tested at the inlet to the motor on deck #1.
4. Install hydraulic flow meter in series with the the dis-
connected hose and deck motor inlet.
5. Make sure the flow control valve on the tester is fully
open.
CAUTION
Keep away from decks during test to prevent per-
sonal injury from the cutting blades.
6. Start engine and move throttle to full speed
(2800 +
50 RPM)
. Engage the cutting units.
7. Watch pressure gauge carefully while slowly closing
the flow control valve to fully closed.
8. As the relief valve lifts, system pressure should be
3400 to 3750 PSI
.
9. Disengage cutting units. Shut off engine. If specifica-
tion is
not
met, clean or replace relief valve (PRV1 or
PRV2) located in the hydraulic deck control manifold
(Fig. 33 and 34).
10.Disconnect tester from motor and hose. Reconnect
hydraulic hose to deck motor.
1. Pressure IN
2. Pressure OUT
3. Case drain
Figure 32
Rotation Direction
3
1
2
1. Deck 2, 3, & 5 relief valve (pump section P2)
2. Deck 1 & 4 relief valve (pump section P1)
Figure 33
GM 4500--D DECK CONTROL MANIFOLDS
1
2
1. Deck 2, 3, 5, & 7 relief valve (pump section P2)
2. Deck 1, 4, & 6 relief valve (pump section P1)
Figure 34
2
GM 4700--D DECK CONTROL MANIFOLDS
1
Hydraulic System
Summary of Contents for Groundsmaster 4500-D
Page 1: ...Form No 02104SL Rev E Groundsmaster 4500 D 4700 D Original Instructions EN ...
Page 4: ...NOTES _ ...
Page 6: ...Groundsmaster 4500 D 4700 D This page is intentionally blank ...
Page 8: ...Groundsmaster 4500 D 4700 D This page is intentionally blank ...
Page 14: ...Groundsmaster 4500 D 4700 D Page 1 6 Safety This page is intentionally blank ...
Page 126: ...Groundsmaster 4500 D 4700 D Hydraulic System Rev A Page 4 88 This page is intentionally blank ...
Page 226: ...Groundsmaster 4500 D 4700 D Page 7 12 Chassis This page is intentionally blank ...
Page 261: ...Rev D Page 9 13 This page is intentionally blank ...
Page 277: ...Rev D Page 9 29 Serial Number Above 230000000 Engine Wire Harness Groundsmaster 4500 D 4700 D ...