![Toro Groundsmaster 4000 Operator'S Manual Download Page 66](http://html.mh-extra.com/html/toro/groundsmaster-4000/groundsmaster-4000_operators-manual_1133577066.webp)
g020451
Figure 99
1.
Battery
2.
Remove the rubber boot from the positive
terminal and inspect the battery.
WARNING
Battery terminals or metal tools could
short against metal components causing
sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
•
When removing or installing the
battery, do not allow the battery
terminals to touch any metal parts of
the machine.
•
Do not allow metal tools to short
between the battery terminals and
metal parts of the machine.
WARNING
Incorrect battery cable routing could
damage the machine and cables causing
sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
•
Always
disconnect
the negative
(black) battery cable before
disconnecting the positive (red)
cable.
•
Always
connect
the positive (red)
battery cable before connecting the
negative (black) cable.
3.
Coat both battery connections with Grafo 112X
(skin-over) grease, Toro Part No. 505-47,
petroleum jelly, or light grease to prevent
corrosion.
4.
Slide the rubber boot over the positive terminal.
5.
Close the battery cover.
Locating the Fuses
The traction-unit fuses are located under the
power-center cover (
,
, and
Remove the 2 screws securing the power-center
cover to the frame and remove the cover (
).
g020440
Figure 100
1.
Power-center cover
2.
Screws
g020439
Figure 101
1.
Fuses
g243209
Figure 102
The cab fuses are located in the fuse box in the cab
headliner (
and
).
Note:
Cab model only
66