CAN bus Communications
The machine controllers communicate with each other on a Controller Area
Network (CAN) bus system. Using this network allows full integration of all the
different electrical components of the machine, allowing them to operate together
as one. The integration of the controllers allows the InfoCenter display to
access machine settings, calibrate various machine components, and assist with
electrical system diagnostics. The key switch needs to be in the R
UN
or S
TART
position for the components on the network to be activated.
Controllers that operate on 12 VDC connect to the 12V side of the CAN bus
(CAN A), while controllers that operate on 48 VDC connect to the 48V side of the
CAN bus (CAN B). The two sides of the CAN bus communicate as one network
through the use of a CAN bus Isolation Module.
IMPORTANT
Logic voltage must be present at the controller before communication
with that controller can occur on the CAN bus.
The entire CAN bus is made up of two specially designed twisted wires. The
engineering term for these wires are CAN High (yellow wire) and CAN Low
(green wire). A 120 ohm CAN termination resistor is located at each end of
CAN A, and at each end of CAN B (4 total). Refer to
for
CAN bus testing procedures.
The Toro DIAG electronic control diagnostics service system is available to
Authorized Toro Distributors to support machine fault diagnosis and maintenance
services of the machine electrical control devices. The Toro DIAG connector is
part of the CAN bus and is located at the rear of the console armrest.