Gre e nK e e pe r 2 1 2 Com pone nt s
The following are brief descriptions of the controller com-
ponents and display elements. Each of these items will
be explained in further detail within the appropriate pro-
gramming, operating and installation sections of this
guide.
1 - LCD Display
A -
“Start Time” symbol – Alarm clock is displayed
when setting the program start times.
B -
Program start time identification numbers 1
–
4.
C -
Main display of various time values and prompts.
D -
Program A, B and C identifiers.
E -
“
Watering On
”
symbol
–
Water droplet indicates a
watering station is running. Droplet flashes if water-
ing is paused.
F -
“
Watering Off
”
symbol
–
Water droplet with slash
indicates all watering activity is Off.
G -
“
Power Off
”
symbol
–
Displayed when 24 V a.c. is
disconnected and controller is on battery power
only.
H -
“
Low Battery Voltage
”
symbol
–
Indicates low bat-
tery voltage (when transformer is disconnected).
I -
Watering Station identification numbers.
J -
“
Percent
”
symbol
–
Indicates the Season Adjust
feature is in use.
K -
Day of the week identifiers.
L -
“
Run Time
”
symbol
–
Hourglass is displayed when
setting the watering station run times.
2 - Control Buttons
+/
ON
button
–
Increases the time display, scrolls for-
ward through the program information and selects
watering days.
–/
OFF
button
–
Decreases the time display, scrolls
backward through the program information and
removes watering days.
N EX T
button
–
Advances to the next portion of pro-
gram information. Resumes watering if paused.
Advances through stations manually when watering.
M AN U AL ST ART
button
–
Selects and starts manual
watering operations.
3 - Control Dial
–
Selects all controller programming
and operation controls (except Manual Start).
Control Dial Positions
RU N
–
The normal dial position for all automatic
and manual operations.
CU RREN T T I M E
/
DAY
–
Enables the clock time
and day to be set.
WAT ERI N G DAY S
–
Enables the watering day
schedules to be set and reviewed.
PROGRAM ST ART T I M E
–
Enables the program
start times to be set and reviewed.
ST AT I ON T I M ES
–
Enables the station run time to
be set and reviewed.
(continued)
3