Toro FLX34 Series Installation And Service Instructions Manual Download Page 2

Nozzle Performance Chart

 

FLX34 Series Performance Chart—25°

Front

Nozzle

Positions

Nozzle Set 31 

 

 

(Yellow)

Nozzle Set 32 

 

(Blue)

Nozzle Set 33 

 

(Brown)

Nozzle Set 34 

 

(Orange)

Nozzle Set 35 

 

(Green)

Nozzle Set 36 

(Gray)

Nozzle Set 37 

(Black)

102-0725

102-7001

102-0727

102-7002

102-6908

102-0730

102-4261

Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335

Back

Nozzle

Positions

Yellow

Blue

Yellow

Orange

Yellow

Red

Yellow

Beige

Yellow

Beige

Yellow

Red

Yellow

Gray

102-6937 102-2925 102-6937 102-2926 102-6937 102-2928 102-6937 102-2929 102-6937 102-2929 102-6937 102-6944 102-6937 102-6945

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

57

13.0

58

15.5

64

21.9

68

24.4

65

58

14.6

60

18.0

68

24.4

72

28.1

76

32.2

80

60

16.2

63

20.5

72

26.9

76

31.1

80

35.6

83

38.2

85

41.5

100

62

17.9

66

23.4

75

29.8

79

34.9

84

39.3

88

43.4

91

46.9

FLX34 Series Performance Chart—15°

Stator

102-6929 Blue

102-1940 White

Conver-

sions

FLX34-3134

FLX34-3537

 Not recommended at these pressures. Radius shown in feet. 

Toro recommends the use of a 1

1

4

" swing joint at flows over 25-GPM (95-LPM). 

Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.

Actual site conditions must be considered when selecting the appropriate nozzle.

All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

52

12.9

53

15.6

60

21.7

62

25.5

65

53

14.4

54

17.1

61

24.2

64

28.0

67

32.1

80

56

16.0

57

19.0

65

26.6

69

31.0

73

35.5

76

38.0

77

41.3

100

57

17.5

59

20.5

67

29.5

71

33.9

75

38.4

80

43.1

81

46.8

FLX54 Series Performance Chart—25°

Front

Nozzle

Positions

Nozzle Set 51 

 

(Yellow)

Nozzle Set 52 

 

(Blue)

Nozzle Set 53 

 

(Brown)

Nozzle Set 54 

 

(Orange)

Nozzle Set 55 

 

(Green)

Nozzle Set 56 

(Gray)

Nozzle Set 57 

(Black)

Nozzle Set 58 

 

(Red)

Nozzle Set 59 

 

(Beige)

102-0725

102-7001

102-0727

102-7002

102-6908

102-0730

102-4261

102-4260

102-4259

Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug

Brown

Red Plug

Brown

Red Plug Red Plug

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-6883 102-4335 102-6883 102-4335 102-4335

Back

Nozzle

Positions

Yellow

Blue

Yellow

Orange

Yellow

Red

Yellow

Beige

Yellow

Beige

Yellow

Red

Yellow

Gray

Yellow

Gray

Yellow

Gray

102-6937 102-2925 102-6937 102-2926 102-6937 102-2928 102-6937 102-2929 102-6937 102-2929 102-6937 102-6944 102-6937 102-6945 102-6937 102-6945 102-6937 102-6945

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

58

13.2

59

15.7

64

22.0

70

26.2

65

60

14.8

61

17.5

68

24.8

74

29.3

79

34.2

80

61

16.4

64

20.0

72

27.6

78

32.6

83

38.0

85

40.7

87

44.9

91

50.2

96

55.6

100

63

18.1

67

23.6

75

30.4

81

36.7

87

42.5

90

45.8

93

50.2

95

55.4

99

61.8

FLX54 Series Performance Chart—15°

Stator

102-6929 Blue

102-1940 White

102-1941 White

Conver-

sions

FLX54-5154

FLX54-5558

FLX54-59

 Not recommended at these pressures. Radius shown in feet. 

Toro recommends the use of a 1

1

4

" swing joint at flows over 25-GPM (95-LPM). 

Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.

Actual site conditions must be considered when selecting the appropriate nozzle.

All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

52

13.2

53

15.8

61

22.0

65

26.0

65

53

14.8

54

17.4

63

24.8

67

29.2

69

34.1

80

56

16.4

58

19.4

68

27.6

72

32.5

75

37.8

79

40.4

81

44.6

85

49.9

87

55.3

100

58

18.1

60

21.1

71

30.4

75

36.4

79

42.3

84

45.5

87

49.9

89

55.1

94

61.5

Summary of Contents for FLX34 Series

Page 1: ...e 13 46 9 GPM 49 2 177 5 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 Recommended Operating Pressure 65 100 PSI 4 5 6 9 Bar Minimum Pressure 40 PSI 2 8 Bar Maximum Pressure 150 PSI 10 3 Bar...

Page 2: ...le Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set 55 Green Nozzle Set 56 Gray Nozzle Set 57 Black Nozzle Set 58 Red Nozzle Set 59 Beige 102 0725...

Page 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Page 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Page 5: ...rom the provided slot in the cap Pull the riser assembly until there is enough clearance for handling and hold onto the riser body Step 2 Remove cap screw and cap to unlock the main nozzle Step 3 Use...

Page 6: ...tween stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly defective Replace riser assembly Head sticks up Dirt in riser assembly Flush out See Fl...

Page 7: ...pen Hydraulic Plugged controller discharge line or discharge port in pilot valve Verify by checking for discharge at discharge line when station is activated If no discharge refer to Controller Servic...

Page 8: ...roove in body Hold onto the riser body 16 and carefully extract it from the sprinkler body CAUTION The seal retainer 12 will rapidly move upward caused by the decompressing spring 14 as it clears the...

Page 9: ...lable use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FLX34 or 995 101 for...

Page 10: ...7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveling ad...

Page 11: ...NOTES...

Page 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0858 Rev A...