1. Unfolding the Handle
Procedure
1. Cut the plastic tie that secures the control cable to
the handle.
Note:
Hold the cable taut to ensure that it stays
connected at the bottom.
2. Loosen the knobs, pull out the handle bolts, and
rotate the upper handle to the operating position
(Figure 3).
G009177
Figure 3
3. Hook the end of the control cable spring into the
bottom hole of the control bar (Figure 4).
Figure 4
4. Fully insert the handle bolts (Figure 5).
Important:
Ensure that you do not pinch the
control cable (Figure 5).
Figure 5
5. Tighten the knobs until they are snug.
6. Adjust the control cable. Refer to Adjusting the
Control Cable.