Maintenance Service
Interval
Maintenance Procedure
Every 300 hours
• Check and adjust the valve clearance. Contact an Authorized Service Dealer.
Before storage
• Charge the battery and disconnect the battery cables.
• Perform all maintenance procedures listed above before storage.
• Paint any chipped surfaces.
CAUTION
If you leave the key in the switch, someone could accidently start the engine and seriously
injure you or other bystanders.
Shut off the engine and remove the key from the switch before you perform any maintenance.
Pre-Maintenance
Procedures
Raising the Machine
Use jackstands to support the machine when you
raise it.
WARNING
Supporting the machine on the lower muffler
shield (
) may damage the shield and
cause the machine to fall, injuring you or
bystanders.
Do not use the lower muffler shield to support
the machine.
g299647
Figure 29
1.
Lower muffler shield
Lubrication
Greasing the Bearings
Service Interval:
Every 25 hours—Grease the caster
wheel bearings.
Grease Type:
No. 2 lithium grease
1.
Park the machine on a level surface, disengage
the blade-control switch, and move the
motion-control levers outward to the P
ARK
position.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Clean the grease fittings (
) with a rag.
Note:
Scrape any paint off the front of the
fitting(s).
g032432
Figure 30
1.
Front caster tire
4.
Connect a grease gun to each fitting (
).
5.
Pump grease into the fittings until grease begins
to ooze out of the bearings.
6.
Wipe up any excess grease.
27