Use the cleaners and neutralizers as
recommended by the chemical manufacturers.
•
Use pure, clean water (no cleaners or neutralizers)
for the
last
rinse.
1.
Fill the tank with at least 190 L (50 US gallons)
of clean, fresh water and close the cover.
Note:
You can use a cleaning/neutralizing
agent in the water as needed. On the final rinse,
use only clean, clear water.
2.
Lower the outer spray sections into the spray
position.
3.
Start the engine and move the throttle lever to a
higher engine speed.
4.
Ensure that the agitation switch is in the O
N
position.
5.
Set the spray-pump switch to the O
N
position
and use the application-rate switch to increase
the pressure to a high setting.
6.
Set the individual section switches and master
section switch to the O
N
positions to begin
spraying.
7.
Allow all of the water in the tank to spray out
through the nozzles.
8.
Check the nozzles to ensure that they are all
spraying correctly.
9.
Set the master section switch to the O
FF
position, set the spray-pump switch to the O
FF
position, and shut off the engine.
10.
Repeat steps
through
at least 2 more times
to ensure that the spray system is fully cleaned.
Important:
You must always complete this
procedure at least 3 times to ensure that the
spray system and spray accessories are fully
clean, preventing damage to the system.
11.
Clean the strainer; refer to
.
Important:
If you used wettable powder
chemicals, clean the strainer after each tank.
12.
Using a garden hose, rinse off the outside of the
sprayer with clean water.
13.
Remove the nozzles and clean them by hand.
Note:
Replace damaged or worn nozzles.
Setting the Section-Bypass
Valves
Manual Mode Only
Important:
When operating in application rate
mode, you must set the section-bypass valves to
the closed position.
Before using the sprayer for the first time, if you
change the nozzles, or as needed, calibrate the
sprayer flow, speed, and set the section bypass; refer
to
Setting the Section-Bypass Valves (page 38)
.
Note:
Calibrate the section valves whenever you
change the nozzles.
Select an open flat area to perform this procedure.
1.
Fill the spray tank halfway with clean water.
2.
Lower the spray sections.
3.
Engage the parking brake.
4.
Set the spray control switch to manual.
5.
Set the 3 section switches to the O
N
position,
but leave the master section switch in the O
FF
position.
6.
Set the spray-pump switch to the O
N
position,
and turn on the agitation.
7.
On the InfoCenter, navigate to the Calibration
screen and select Test Speed; refer to
Simulating a Test Speed in the
Software Guide
for the Multi Pro 5800-D and 5800-G turf sprayer
with ExcelaRate spray system.
A.
Press buttons 3 or 4 to raise or lower the
simulated speed to 5.6 km/h (3.5 mph).
B.
Press button 4 to toggle O
N
test speed
simulation.
C.
Press button 5 to save and exit the
TEST
SPEED
screen.
8.
Using the application-rate switch, adjust the
application rate according to the table that
follows.
38
Summary of Contents for 41393
Page 88: ...Schematics g034336 Sprayer System Schematic Rev DWG 131 9559 Rev A 88...
Page 89: ...Notes...
Page 90: ...Notes...