Replacing the Reel Cable
g336876
Figure 80
1.
Reel cable
6.
V-ring seal
11.
Clevis pin
2.
Jam nut
7.
Reel lever assembly
12.
Upper receiver weldment
3.
Cable spring
8.
Cotter pin clip
13.
Retaining ring
4.
Knob
9.
Split bushing
5.
Reel lever handle rod
10.
Clevis connector
Removing the Reel Cable
Note:
Refer to
during this procedure.
1. Ensure that the cutting-unit-drive lever is in the D
ISENGAGE
position, park the
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
FF
, and remove the key; refer to
the
Operator's Manual
.
2. Disconnect the battery pack; refer to
Disconnecting and Connecting the
Lithium Battery Pack (page 5–3)
.
Greensmaster
®
eFlex 1021
Page 6–7
Controls, Wheels, and Accessories : Service and Repairs
20248SL Rev C
Summary of Contents for 04861