Main Contactor
g339029
Figure 62
1.
Contactor
3.
TEC
2.
Bolt (2 each)
The Greensmaster eFlex machines use the main contactor to connect the lithium
battery pack and the electric motor. The contactor is energized by the TEC.
The contactor is attached to the battery mount under the battery cover; refer
to
Note:
When the key switch is turned to the O
N
position, the contactor inside
the battery pack will be energized followed shortly by the main contactor being
energized. There should be an audible click as each of these contactors are
energized.
Note:
A damaged main contactor may cause a #16 fault to be generated
and displayed on the InfoCenter. Refer to the
Faults Screen (page 5–15)
for
information on faults.
Testing the Main Contactor
1. Ensure that the cutting-unit-drive lever is in the D
ISENGAGE
position, park the
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
FF
, and remove the key; refer to
the
Operator's Manual
.
2. Disconnect the battery pack; refer to
Disconnecting and Connecting the
Lithium Battery Pack (page 5–3)
.
3. Remove the four bolts that secures the battery cover to the battery mount.
Remove the battery cover from the machine.
Electrical System: Testing the Electrical Components
Page 5–36
Greensmaster
®
eFlex 1021
20248SL Rev C
Summary of Contents for 04861
Page 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Page 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Page 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Page 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Page 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Page 234: ......