Toro 02891 Operator'S Manual Download Page 5

1

2

3

g018436

Figure 4

Condenser and dryer/filter—mounted in rear of the cab roof

1.

Condenser

3.

Pressure switch

2.

Dryer/filter

Controls

The controls are mounted on the right side in the roof lining.

G025784

1

2

0

3

Figure 5

1.

3-position switch for
radial-blower speed

3.

Air-conditioner switch

2.

Temperature controller

5

 

Summary of Contents for 02891

Page 1: ...Form No 3395 604 Rev A Air Conditioning Kit Mauser KS 534 Full Safety Cab Model No 02891 Register at www Toro com Original Instructions EN 3395 604 A...

Page 2: ...numbers of your product ready Write the numbers in the space provided Model No Serial No This manual identifies potential hazards and has safety messages identified by the safety alert symbol Figure...

Page 3: ...mosphere Never attempt to warm any part of the air conditioning system with an open flame Never allow refrigerant to come into contact with the skin Refer to the refrigerant data sheet for guidance We...

Page 4: ...4 1 2 3 Figure 2 Evaporator heater and fans mounted in front of the cab roof 1 Air conditioner evaporator heater and double radial blower 3 Expansion valve 2 Heater valve g018399 Figure 3 Compressor...

Page 5: ...n rear of the cab roof 1 Condenser 3 Pressure switch 2 Dryer filter Controls The controls are mounted on the right side in the roof lining G025784 1 2 0 3 Figure 5 1 3 position switch for radial blowe...

Page 6: ...l performance of your Toro equipment count on Toro genuine parts When it comes to reliability Toro delivers replacement parts designed to the exact engineering specification of our equipment For peace...

Page 7: ...m for many months of the cutting season Follow the regular prescribed maintenance to prolong the life of the system and ensure efficient operation Failure to carry out the prescribed and documented ma...

Page 8: ...rigerant quantity is too low check the sight glass The compressor speed is too low check the drive belt for slip tension There is a fault with the compressor Pressure on low pressure manometer too hig...

Page 9: ...he cab Figure 8 Check the water drain for blockages and clean as necessary If the tube is blocked use a flexible unblocking tool pipe cleaner or disconnect the tube and blow it out with compressed air...

Page 10: ...n the bolts 4 Check the deflection of the belt again to ensure that the tension is correct Locating the Fuses The fuse box is located in the cab roof liner in front of the driver g018402 1 2 3 4 Figur...

Page 11: ...Schematics g01840 1 2 1 3 4 9 8 5 6 10 7 11...

Page 12: ...pansion valve 3 Evaporator combined with heat exchanger for heating 4 Condenser water 5 Compressor 6 Condenser 7 Axial fans 8 Dryer filter 9 Sight glass 10 Drain Functional schematic of the air condit...

Page 13: ...5A 7 in 5k 1 1 2 2 L M B H C 3 3 6 5 4 30 87 85 86 30 87 84 85 30 A 15 A 5A 4 in 5k 6 in 5k 3 in 5k 23 A 30 87 85 86 30 15 1 2 4 6 7 9 5 10 8 3 10 g019147 13...

Page 14: ...netic clutch 3 Twin axial fans 4 Temperature sensor 5 Electronic regulator 6 Radial blower fan 7 Blower speed switch 8 Pressure switch 9 Main fuse in engine compartment 10 Relay Electrical schematic o...

Page 15: ...ompiled as required per Part B of Annex VII of 2006 42 EC We will undertake to transmit in response to requests by national authorities relevant information on this partly completed machinery The meth...

Page 16: ......

Reviews: