SAFETY REGULATIONS
– ROBOBAR MSF–522/6 & ROBOBAR MSF–832/6
300286 E – 02/01
Chap. 6.5.1 /6
6.5
EMERGENCY STOP AND CONTROL PANEL
Components
SB1 Emergency stop pushbutton
1070 Operator control panel
SA9
SB6
SB9
SB8
SB7
SA8
SB3
SA2
SB5
SB1
fig. 3
SB1
6.5.1 Emergency stop
Emergency stop pushbutton SB1 is a mushroom-like pushbutton with a lock.
It is located on operator control panel according fig. 3.
⇒
Information :
The emergency stop of the barfeeder is directly connected to the emer-
gency stop of the machine. They ensure both the same function.
Emergency stop operation
When you press the emergency stop, all elements of the machine and of the
barfeeder will instantaneously come to a halt except for the air conditioning
of the electric cabinet.
Once pressed, the emergency stop sets all controls out of operation.
Emergency stop inspection
⇒
Information :
Check regularly the emergency stop operation.
Restarting after emergency stop
RESTARTING
MACHINE AND BARFEEDER
To start with: after having activated the emergency stop pushbutton
What to do ?
How & Notes
Remedy the cause of the stop.
See also overleaf.
Unlock the activated pushbutton.
Turn the pushbutton clockwise.
Restart the machine and the bar–
feeder
Consult the instruction entitled
USER INTERFACE OPERATION