background image

SENSA T 

Motion sensor. Turns on the light when the user opens the door and turns off it

automatically after a fixed time. The timer countdown is activated everytime a movement of the 

door is detected. It can be installed in every tipe of swing door, folding door, drawer and light

sliding door.

SENSA M 

Motion and magnetic sensor. Turns on the light when the user opens the

door and turns off it automatically after a fixed time or recognizing a magnetic

contact. The timer countdown is activated everytime a movement of the door is detected.

It can be installed in every tipe of door and drawer. Suggested for heavy and damped

SENSA

-T 

SENSA

-M

INDEX

1 - PRODUCT FEATURES

 

1.1 - TECHNICAL DATA

2 - PREPARATION ON DOOR

 

2.1 - SENSOR DIMENSIONS AND WORK ON DOOR

 

2.2 - POSITION OF REED CONTACT FOR MAGNET

 

2.3 - MAGNET INSTALLATION 

3 - DESCRIPTION OF THE SENSOR

 

3.1 - DESCRIPTION 

 

3.2 - USE OF THE SENSOR

4 - RADIO PROGRAMMING

5 - RADIO DELETION 

6 - SETTING SENSOR SENSITIVITY

www .lightengineering.net

Tormene 

  group

LIGHT ENGIN DESIGN SRL
Via Spagna, 6 - 35010 Vigonza (PD)
Ph. +39 049 0980809
Email: [email protected]
Web: www.lightengineering.net

Tormene 

  group

07/2019_Rev 1.1

Summary of Contents for LE+D SENSA M

Page 1: ...t automatically after a fixed time or recognizing a magnetic contact The timer countdown is activated everytime a movement of the door is detected It can be installed in every tipe of door and drawer...

Page 2: ...m 20 m inside a building Motion recognition SENSA M SENSA T Motion recognition and magnetic contact Power supply Battery life Code Frequency Range Technology 1 PRODUCT FEATURES Top screws Top joint Ex...

Page 3: ...www lightengineering net...

Page 4: ...ON 2 PREPARATION ON DOOR Reed sensor for magnet Preparation hole for self tapping screws with countersunk head Max screw diameter 3 5mm 64 8mm 89 8mm 9 8mm 38 8mm 65mm 90mm 4mm 10mm 39mm 10mm 39mm 9 8...

Page 5: ...A2 POSITION A3 A1 B1 N S N N S S N S N S N S D1 C1 C2 C3 D3 D2 B2 A2 A3 B3 POSITION D1 POSITION D2 POSITION D3 A1 with MAG153A max 15mm A1 con MAG225A max 30mm B1 5mm A2 con MAG153A max 15mm A2 con M...

Page 6: ...a movement it sends a command to switch on the light to the receiver it is associated with Switching off is carried out through a timer in the receiver see receiver manual SENSA M with magnet present...

Page 7: ...turn on If you take your finger off on blu the sensor will make LIGHT1 turn on If you take your finger off on yellow the sensor will make LIGHT1 turn on NOTE Make a note on the label of the serial nu...

Page 8: ...ver manual 5 1 DELETION OF THE SENSOR FROM THE RECEIVER STEP 1 Press the button on the sensor for a short time The LED comes on green and stays on STEP 3 Press the button on the sensor for a short tim...

Page 9: ...The LED flashes blue STEP 4 To change the setting repeat the procedure from point 1 the control unit will alternate between 3 and 6 flashes STEP 3 Count the number of flashes emitted by the LED 3 flas...

Page 10: ...y and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particula...

Page 11: ...www lightengineering net...

Page 12: ...LIGHT ENGINEERING DESIGN SRL Via Spagna 6 35010 Vigonza PD Ph 39 049 0980809 Email info lightengineering net Web www lightengineering net Torme ne group 07 2019_Rev 1 1...

Reviews: